This document presents the test results for spurious emissions, both conducted and radiated, for the Tait TMCN0B device. The tests were performed by Teltest Laboratories and are documented in report number 4402. The report adheres to FCC 47 CFR 2.1051, FCC 47 CFR 90.543, TIA-603-E 2.2.14, TIA-102.CAAA-E 2.2.8, and RSS-119 5.8 standards.
The conducted emissions testing involved examining the frequency range from the lowest frequency generated within the EUT up to the 10th harmonic. The transmitter was tested at both high and low power settings. The radiated emissions testing involved initial scans in a TEM cell and reverberation chamber, followed by measurements on an Open Area Test Site (OATS) for emissions close to the limit. The report includes detailed measurement procedures, equipment setup information, and tabular results showing emission frequencies, levels, and compliance with specified limits.
The document also includes sample calculations for attenuation correction and provides photographs of the test setup. The results indicate that the TMCN0B device meets the required spurious emissions standards.