EMC Test Report: XP Metal Detectors DELLFMFHP Compliance

Test Report

This document presents the EMC (Electromagnetic Compatibility) test report for the XP Metal Detectors model DELLFMFHP. The report details the testing procedures and results conducted to ensure compliance with regulations set forth by the Federal Communications Commission (FCC) under Part 15 Subpart C, and Innovation, Science and Economic Development Canada (ISED) under RSS-Gen Issue 5 and RSS-210 Issue 11.

The tests were performed by Element Materials Technology Fremont (AKA: NTS Labs, LLC) and include assessments of radiated and conducted emissions. The report provides information on the equipment under test (EUT), test setup, measurement instrumentation, and detailed test data. The objective of the testing was to verify that the DELLFMFHP model meets the required emission limits and complies with the specified regulatory standards for operation in the United States and Canada.

The report also includes information on measurement uncertainties, test site details, and a list of test equipment used. The test results indicate that the XP Metal Detectors model DELLFMFHP complies with the applicable FCC and ISED regulations.


File Info : application/pdf, 0 Pages, 746.33KB

Download

tags: ["DELLFMFHP", "XP Metal Detectors", "FCC Part 15 Subpart C", "RSS-Gen Issue 5", "RSS-210 Issue 11", "8392A- DELLFMFHP", "XFJDELLFMFHP"]
Array
(
    [0] => Array
        (
            [url_sha] => 070dd327ade693d3eb3856dd420a521d5b1d069e8744a0cdab92943120ef68f7
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8263635
            [href_text] => Test Report
            [href_description] => XPLORER DELLFMFHP DELLFMFHP XFJDELLFMFHP XFJDELLFMFHP dellfmfhp
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8263635
            [http_size] => 764245
            [file_sha256] => 50aa27fcb8f97589d45db0b9438cd8960279c4a8a51ca525a85cfc1c819c113a
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => 32352f8cad2e234ca45fc13b784ca8af5d1d59ea7caad67733f3c8892e080372
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8263587
            [href_text] => Test Report
            [href_description] => XPLORER DELLFMFHP DELLFMFHP XFJDELLFMFHP XFJDELLFMFHP dellfmfhp
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8263587
            [http_size] => 764245
            [file_sha256] => 50aa27fcb8f97589d45db0b9438cd8960279c4a8a51ca525a85cfc1c819c113a
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 50aa27fcb8f97589d45db0b9438cd8960279c4a8a51ca525a85cfc1c819c113a
    [cleanFccId] => XFJDELLFMFHP
    [title] => EMC Test Report: XP Metal Detectors DELLFMFHP Compliance
    [description] => EMC test report for XP Metal Detectors DELLFMFHP, verifying compliance with FCC and Canada regulations. Includes test data and equipment details.
    [brand_name] => Element
    [keywords] => ["DELLFMFHP", "XP Metal Detectors", "FCC Part 15 Subpart C", "RSS-Gen Issue 5", "RSS-210 Issue 11", "8392A- DELLFMFHP", "XFJDELLFMFHP"]
    [intro] => 

This document presents the EMC (Electromagnetic Compatibility) test report for the XP Metal Detectors model DELLFMFHP. The report details the testing procedures and results conducted to ensure compliance with regulations set forth by the Federal Communications Commission (FCC) under Part 15 Subpart C, and Innovation, Science and Economic Development Canada (ISED) under RSS-Gen Issue 5 and RSS-210 Issue 11.

The tests were performed by Element Materials Technology Fremont (AKA: NTS Labs, LLC) and include assessments of radiated and conducted emissions. The report provides information on the equipment under test (EUT), test setup, measurement instrumentation, and detailed test data. The objective of the testing was to verify that the DELLFMFHP model meets the required emission limits and complies with the specified regulatory standards for operation in the United States and Canada.

The report also includes information on measurement uncertainties, test site details, and a list of test equipment used. The test results indicate that the XP Metal Detectors model DELLFMFHP complies with the applicable FCC and ISED regulations.

)
Array
(
    [0] => Array
        (
            [id] => 8263587
            [file_sha256] => 
            [applicationId] => hhc+VZCzXMczz8BMH+aPQg==
            [description] => Test Report
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => Test Report
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 764247
            [submissionDate] => 2025-05-06 00:00:00
            [dateAvailable] => 2025-05-06 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => XFJDELLFMFHP
            [cleanFccId] => XFJDELLFMFHP
            [exif] => 0
        )

)