U7-Pro-XGS WiFi 7 Test Report: FCC Part 15 Subpart E

Test Report UNII 5

This document presents a detailed test report for the Ubiquiti U7-Pro-XGS WiFi 7 access point, evaluating its compliance with the Federal Communications Commission (FCC) Part 15, Subpart E regulations. The testing was conducted by Unified Compliance Laboratory (UCL) and covers a range of measurements, including conducted emissions at mains ports, direct connect antenna port tests, radiated emissions, and contention-based protocol tests.

The report provides comprehensive data on the device's performance across various operating modes and frequency bands, including 26 dB emissions bandwidth, maximum average output power, spurious emissions, and maximum power spectral density. The results demonstrate that the U7-Pro-XGS meets the specified requirements and complies with the applicable FCC regulations. The report also includes detailed information on the test equipment used, measurement procedures, and uncertainty analysis.

This report serves as evidence of the U7-Pro-XGS's adherence to regulatory standards, ensuring its safe and compliant operation within the designated frequency spectrum.


File Info : application/pdf, 38 Pages, 1.78MB

Download
Microsoft Word 2016 Microsoft Word 2016
tags: ["U7-Pro-XGS", "SWX-U7PROXS", "6545A-U7PROXS", "WiFi 7", "FCC Part 15 Subpart E"]
Array
(
    [0] => Array
        (
            [url_sha] => 7e4eff98470da945300f2c4334bb69bab52dde165b47ca196639d77b676fe82c
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8102786
            [href_text] => Test Report UNII 5
            [href_description] => Ubiquiti Inc. U7PROXS Digital Transmission Radio SWX-U7PROXS SWXU7PROXS u7proxs
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8102786
            [http_size] => 1863419
            [file_sha256] => 4ed9d9fdaba545b4aabf0bc33e37296b68381d40fe941c8931640f16b1372694
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => 8afd9b35f3d2d222116b5a9fae19869e1e2100252ab56da2f2f0a235d15c9421
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8102828
            [href_text] => Test Report UNII 5
            [href_description] => Ubiquiti Inc. U7PROXS Digital Transmission Radio SWX-U7PROXS SWXU7PROXS u7proxs
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8102828
            [http_size] => 1863419
            [file_sha256] => 4ed9d9fdaba545b4aabf0bc33e37296b68381d40fe941c8931640f16b1372694
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 4ed9d9fdaba545b4aabf0bc33e37296b68381d40fe941c8931640f16b1372694
    [cleanFccId] => SWXU7PROXS
    [title] => U7-Pro-XGS WiFi 7 Test Report: FCC Part 15 Subpart E
    [description] => Comprehensive test report for the Ubiquiti U7-Pro-XGS WiFi 7 access point, detailing compliance with FCC Part 15 Subpart E regulations. Includes conducted and radiated emissions data.
    [brand_name] => Ubiquiti
    [keywords] => ["U7-Pro-XGS", "SWX-U7PROXS", "6545A-U7PROXS", "WiFi 7", "FCC Part 15 Subpart E"]
    [intro] => 

This document presents a detailed test report for the Ubiquiti U7-Pro-XGS WiFi 7 access point, evaluating its compliance with the Federal Communications Commission (FCC) Part 15, Subpart E regulations. The testing was conducted by Unified Compliance Laboratory (UCL) and covers a range of measurements, including conducted emissions at mains ports, direct connect antenna port tests, radiated emissions, and contention-based protocol tests.

The report provides comprehensive data on the device's performance across various operating modes and frequency bands, including 26 dB emissions bandwidth, maximum average output power, spurious emissions, and maximum power spectral density. The results demonstrate that the U7-Pro-XGS meets the specified requirements and complies with the applicable FCC regulations. The report also includes detailed information on the test equipment used, measurement procedures, and uncertainty analysis.

This report serves as evidence of the U7-Pro-XGS's adherence to regulatory standards, ensuring its safe and compliant operation within the designated frequency spectrum.

)
Array
(
    [0] => Array
        (
            [id] => 8102786
            [file_sha256] => 
            [applicationId] => MQebfsTIveA/OToAwi8Q9w==
            [description] => Test Report UNII 5
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => Test Report
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 1863419
            [submissionDate] => 2025-03-07 00:00:00
            [dateAvailable] => 2025-03-07 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => SWX-U7PROXS
            [cleanFccId] => SWXU7PROXS
            [exif] => 0
        )

)