This document presents the method and results from an accredited Specific Absorption Rate (SAR) reference dipole calibration performed by BCTC using the COMOSAR test bench. The calibration adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring traceability to national metrology institutions.
The report details the calibration of various dipoles, including models SID750, SID835, SID1800, SID1900, SID2450, SID2600, and SID5000, with serial numbers and frequencies specified. Key measurements such as return loss and impedance in both head and body liquids are presented, along with mechanical dimensions and validation results.
The calibration process involves assessing the dipole's performance in controlled conditions, ensuring it meets stringent requirements for return loss and impedance. Measurement uncertainties are carefully evaluated and reported, providing confidence in the accuracy of the calibration results. This report serves as a critical component in ensuring the reliability and accuracy of SAR measurements performed using these dipoles.
Array ( [0] => Array ( [url_sha] => a821b40b79e867938f3a9a9f8f174703edc015c98335ff86dc07ab45a30b0035 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8125597 [href_text] => Test Report SAR4 [href_description] => SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 25155 Smart Phone 2ANMU-25155 2ANMU25155 25155 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8125597 [http_size] => 6096680 [file_sha256] => 3967f00365205dd00169dcdbacc46540674aeaefa4993a2f97cf180fb89fa142 [domain] => document.fccid ) [1] => Array ( [url_sha] => 5e388626ac0c2a5d111b70ab6d32c5166345601fdc715eb99119d6f5883a124c [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8125502 [href_text] => Test report SAR4 [href_description] => SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 25155 Smart Phone 2ANMU-25155 2ANMU25155 25155 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8125502 [http_size] => 6096680 [file_sha256] => 3967f00365205dd00169dcdbacc46540674aeaefa4993a2f97cf180fb89fa142 [domain] => document.fccid ) [2] => Array ( [url_sha] => a2a6088f794acc1e41d227c99b1d4c05980d08535a3224305b89ec774eaa4136 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8125360 [href_text] => Test Report SAR4 [href_description] => SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 25155 Smart Phone 2ANMU-25155 2ANMU25155 25155 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8125360 [http_size] => 6096680 [file_sha256] => 3967f00365205dd00169dcdbacc46540674aeaefa4993a2f97cf180fb89fa142 [domain] => document.fccid ) ) Array ( [file_sha256] => 3967f00365205dd00169dcdbacc46540674aeaefa4993a2f97cf180fb89fa142 [cleanFccId] => 2ANMU25155 [title] => BCTC SAR Reference Dipole Calibration Report [description] => Accredited SAR reference dipole calibration report for BCTC, ensuring accurate measurements and compliance with industry standards. [brand_name] => BCTC [keywords] => ["SAR", "Dipole Calibration", "ACR.329.11.24.BES.A", "ACR.329.8.24.BES.A", "EPGO420", "SID750", "SID835", "SID1800", "SID1900", "SID2450", "SID2600", "SID5000", "DIP 0G750-620", "DIP 0G835-621", "DIP 1G800-623"] [intro] =>This document presents the method and results from an accredited Specific Absorption Rate (SAR) reference dipole calibration performed by BCTC using the COMOSAR test bench. The calibration adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring traceability to national metrology institutions.
The report details the calibration of various dipoles, including models SID750, SID835, SID1800, SID1900, SID2450, SID2600, and SID5000, with serial numbers and frequencies specified. Key measurements such as return loss and impedance in both head and body liquids are presented, along with mechanical dimensions and validation results.
The calibration process involves assessing the dipole's performance in controlled conditions, ensuring it meets stringent requirements for return loss and impedance. Measurement uncertainties are carefully evaluated and reported, providing confidence in the accuracy of the calibration results. This report serves as a critical component in ensuring the reliability and accuracy of SAR measurements performed using these dipoles.
)
Array ( [0] => Array ( [id] => 8125360 [file_sha256] => [applicationId] => noSH66lOUYt2Xln/Xzthbw== [description] => Test Report SAR4 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 6096681 [submissionDate] => 2025-03-18 00:00:00 [dateAvailable] => 2025-03-18 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2ANMU-25155 [cleanFccId] => 2ANMU25155 [exif] => 0 ) )