SAR Reference Dipole and Waveguide Calibration Report

SAR Report part 4

This document presents the calibration results for SAR (Specific Absorption Rate) reference dipoles and waveguides. The calibration was performed by MVG (Microwave Vision Group) and adheres to the requirements outlined in IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. The report includes detailed information about the devices under test, including their model numbers, serial numbers, and product conditions.

The calibration process involves mechanical dimension measurements, S11 parameter assessments, and SAR evaluations. Measurement uncertainties are carefully considered and reported. The results demonstrate that the calibrated dipoles and waveguides meet the specified standards for return loss, impedance, and SAR values. The report also includes a list of equipment used during the calibration process, ensuring traceability and reliability of the results.

Appendix E provides justification for extended calibration intervals based on the stability of the dipole's return loss and impedance over time. This justification is based on the criteria outlined in the relevant standards, allowing for potentially reduced calibration frequency while maintaining measurement accuracy.


File Info : application/pdf, 13 Pages, 2.20MB

Download
Microsoft Word 2013
tags: ["SAM Phantom", "COMOSAR Test Bench", "Network Analyzer ZVM", "ZV-Z235", "Keithley 2000", "Keysight U2000A", "Krytar 158020", "Testo 184 H1", "SWG5500", "SN 13/09 SAM68", "MODU-023-C-0002", "SN: MY62340002", "3523-EPGO-429", "3623-EPGO-431", "SN 13/14 WGA33"]
Array
(
    [0] => Array
        (
            [url_sha] => f0943c1e1a61a3c0f0ea47db65bbe1497366c53aae7b543f64000f0843302512
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8259980
            [href_text] => SAR Report part 4
            [href_description] => Imin Technology Pte Ltd I24M01  2AYD5-I24M01 2AYD5I24M01 i24m01
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8259980
            [http_size] => 2311590
            [file_sha256] => 141bf19b47e3e496a64be7467760e5c776ff6ff4f9d21925cefa5e9ebb13f760
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => 2794bfe9ce53a1f59900891061ebf5d978b0aed4fbebe9227d54b5e6cac0fc73
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8259713
            [href_text] => SAR Report part 4
            [href_description] => Imin Technology Pte Ltd I24M01 POS Device 2AYD5-I24M01 2AYD5I24M01 i24m01
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8259713
            [http_size] => 2311590
            [file_sha256] => 141bf19b47e3e496a64be7467760e5c776ff6ff4f9d21925cefa5e9ebb13f760
            [domain] => document.fccid
        )

    [2] => Array
        (
            [url_sha] => 11d9e1d64a438d833366a7bbca6f9eee6c03a49413484e7d65c84ad55ae1864a
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8259762
            [href_text] => SAR Report part 4
            [href_description] => Imin Technology Pte Ltd I24M01  2AYD5-I24M01 2AYD5I24M01 i24m01
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8259762
            [http_size] => 2311590
            [file_sha256] => 141bf19b47e3e496a64be7467760e5c776ff6ff4f9d21925cefa5e9ebb13f760
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 141bf19b47e3e496a64be7467760e5c776ff6ff4f9d21925cefa5e9ebb13f760
    [cleanFccId] => 2AYD5I24M01
    [title] => SAR Reference Dipole and Waveguide Calibration Report
    [description] => This report details the calibration of SAR reference dipoles and waveguides, ensuring compliance with IEC/IEEE and FCC standards for accurate SAR measurements.
    [brand_name] => MVG (Microwave Vision Group)
    [keywords] => ["SAM Phantom", "COMOSAR Test Bench", "Network Analyzer ZVM", "ZV-Z235", "Keithley 2000", "Keysight U2000A", "Krytar 158020", "Testo 184 H1", "SWG5500", "SN 13/09 SAM68", "MODU-023-C-0002", "SN: MY62340002", "3523-EPGO-429", "3623-EPGO-431", "SN 13/14 WGA33"]
    [intro] => 

This document presents the calibration results for SAR (Specific Absorption Rate) reference dipoles and waveguides. The calibration was performed by MVG (Microwave Vision Group) and adheres to the requirements outlined in IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. The report includes detailed information about the devices under test, including their model numbers, serial numbers, and product conditions.

The calibration process involves mechanical dimension measurements, S11 parameter assessments, and SAR evaluations. Measurement uncertainties are carefully considered and reported. The results demonstrate that the calibrated dipoles and waveguides meet the specified standards for return loss, impedance, and SAR values. The report also includes a list of equipment used during the calibration process, ensuring traceability and reliability of the results.

Appendix E provides justification for extended calibration intervals based on the stability of the dipole's return loss and impedance over time. This justification is based on the criteria outlined in the relevant standards, allowing for potentially reduced calibration frequency while maintaining measurement accuracy.

)
Array
(
    [0] => Array
        (
            [id] => 8259713
            [file_sha256] => 
            [applicationId] => T502TfVQtbW2Erwo4BxbVg==
            [description] => SAR Report part 4
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 2311592
            [submissionDate] => 2025-05-02 00:00:00
            [dateAvailable] => 2025-05-02 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2AYD5-I24M01
            [cleanFccId] => 2AYD5I24M01
            [exif] => 0
        )

)