This document presents the results of an accredited SAR reference dipole calibration performed by MVG for Shenzhen BCTC Technology Co., Ltd. The calibration adheres to the requirements outlined in IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring compliance for SAR measurement system validations.
The report details the calibration of two COMOSAR reference dipoles operating at 750 MHz and 835 MHz, identified by serial numbers SN 47/21 DIP 0G750-620 and SN 47/21 DIP 0G835-621, respectively. Key measurements include return loss, impedance, and mechanical dimensions, all verified against specified requirements. Validation measurements were conducted in both head and body liquid configurations to assess the dipoles' performance under simulated operating conditions.
The calibration process and results are traceable to national metrology institutions, providing confidence in the accuracy and reliability of the reported data. This report serves as essential documentation for ensuring the validity of SAR measurements performed using these reference dipoles.
Array ( [0] => Array ( [url_sha] => bba4ae7aab2f16f53d38059591b542f4683993c20f90ed083136ae9c1217fd7d [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8266325 [href_text] => FCCIDSARReport 2 [href_description] => SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 25156 Smart Phone 2ANMU-25156 2ANMU25156 25156 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8266325 [http_size] => 5544098 [file_sha256] => 0362dbb8530d45cf565b34aa57abab9673ed00a53d86d84a8ab1f45d66172515 [domain] => document.fccid ) [1] => Array ( [url_sha] => f070723d385fc0e7c2a73c78ea9ae09054716aec85ec4efa4727a6ef54046d3a [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8266016 [href_text] => FCCIDSARReport 2 [href_description] => SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 25156 Smart Phone 2ANMU-25156 2ANMU25156 25156 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8266016 [http_size] => 5544098 [file_sha256] => 0362dbb8530d45cf565b34aa57abab9673ed00a53d86d84a8ab1f45d66172515 [domain] => document.fccid ) [2] => Array ( [url_sha] => c9913f551490de809cd4dbcd82f312949c887fcc6da90a921f269ec8d402dfc0 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8266103 [href_text] => FCCIDSARReport 2 [href_description] => SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 25156 Smart Phone 2ANMU-25156 2ANMU25156 25156 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8266103 [http_size] => 5544098 [file_sha256] => 0362dbb8530d45cf565b34aa57abab9673ed00a53d86d84a8ab1f45d66172515 [domain] => document.fccid ) ) Array ( [file_sha256] => 0362dbb8530d45cf565b34aa57abab9673ed00a53d86d84a8ab1f45d66172515 [cleanFccId] => 2ANMU25156 [title] => SAR Reference Dipole Calibration Report for BCTC [description] => Accredited SAR reference dipole calibration report by MVG for BCTC. Compliant with IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. [brand_name] => BCTC [keywords] => ["SID750", "SID835", "DIP 0G750-620", "DIP 0G835-621", "SN 47/21", "IEC/IEEE 62209-1528", "FCC KDB865664 D01"] [intro] =>This document presents the results of an accredited SAR reference dipole calibration performed by MVG for Shenzhen BCTC Technology Co., Ltd. The calibration adheres to the requirements outlined in IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring compliance for SAR measurement system validations.
The report details the calibration of two COMOSAR reference dipoles operating at 750 MHz and 835 MHz, identified by serial numbers SN 47/21 DIP 0G750-620 and SN 47/21 DIP 0G835-621, respectively. Key measurements include return loss, impedance, and mechanical dimensions, all verified against specified requirements. Validation measurements were conducted in both head and body liquid configurations to assess the dipoles' performance under simulated operating conditions.
The calibration process and results are traceable to national metrology institutions, providing confidence in the accuracy and reliability of the reported data. This report serves as essential documentation for ensuring the validity of SAR measurements performed using these reference dipoles.
)
Array ( [0] => Array ( [id] => 8266016 [file_sha256] => [applicationId] => AuVot65E6zrtZjpnG2p21A== [description] => FCCIDSARReport 2 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 5544099 [submissionDate] => 2025-05-07 00:00:00 [dateAvailable] => 2025-05-07 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2ANMU-25156 [cleanFccId] => 2ANMU25156 [exif] => 0 ) )