This document summarizes the test results for LTE Band 12, as detailed in SGS report SEWA2309000114RG01. The report includes data on Effective (Isotropic) Radiated Power Output, Peak-to-Average Ratio (CCDF), 26dB Bandwidth and Occupied Bandwidth, Band Edge compliance, and Conducted Spurious Emission. The tests were conducted by SGS-CSTC Standards Technical Services (Suzhou) Co., Ltd.
The report provides detailed tables of results for various bandwidths (1.4MHz, 3MHz, 5MHz, and 10MHz) and modulations (QPSK, 16QAM, 64QAM, and 256QAM) across different channels and RB configurations. All tests passed the specified limits. The frequency stability test results are also included, showing minimal deviation across varying voltage and temperature conditions.
The document includes graphical representations of the test results, such as CCDF plots, occupied bandwidth plots, and band edge plots. These graphs provide a visual confirmation of the device's compliance with regulatory requirements.
Array ( [0] => Array ( [url_sha] => 99c74ba4b26cb4ec3ad86f79c5277e02ea4823d82e08b5eda4c64c1ad1b910a5 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=6907754 [href_text] => Appendix_B.6 [href_description] => Quectel Wireless Solutions Company Limited 2023RM520NGL 5G Sub-6 GHz M.2 Module with WCDMA, LTE and 5GNR XMR2023RM520NGL XMR2023RM520NGL 2023rm520ngl [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=6907754 [http_size] => 4415707 [file_sha256] => fda9c24b3a5d69fb5a1e75c770f766c7da062ed9a204ef14165a1e7074083d0a [domain] => document.fccid ) [1] => Array ( [url_sha] => 19253c9c1f5b608e770259189ef09da4b92d9e8634914664874d2593418d49f5 [source] => crawler [url] => http://www.electric.garden/quectel-wireless-solutions-xmr/test-report/2023RM520NGL-Test-Report-Quectel-Wireless-Solutions-xmr2023rm520ngl-ex-2-20.pdf [href_text] => download (pdf) [href_description] => 2023RM520NGL 5 G Sub 6 G Hz M.2 Module With Wcdma, Lte And 5 Gnr by Quectel Wireless Solutions [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => 2023RM520NGL-Test-Report-Quectel-Wireless-Solutions-xmr2023rm520ngl-ex-2-20 [http_size] => 4415707 [file_sha256] => fda9c24b3a5d69fb5a1e75c770f766c7da062ed9a204ef14165a1e7074083d0a [domain] => www.electric.garden ) [2] => Array ( [url_sha] => d7945f9ce0b575ff65a3f55d7ccc883d5e0461c5a564d307ee2e1cb06fd75648 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8061400 [href_text] => Appendix-B-6-6907754 [href_description] => Beijing InHand Networks Technology Co., Ltd. ER815NRQ3 Edge Router 2AANY-ER815NRQ3 2AANYER815NRQ3 er815nrq3 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8061400 [http_size] => 4415707 [file_sha256] => fda9c24b3a5d69fb5a1e75c770f766c7da062ed9a204ef14165a1e7074083d0a [domain] => document.fccid ) ) Array ( [file_sha256] => fda9c24b3a5d69fb5a1e75c770f766c7da062ed9a204ef14165a1e7074083d0a [cleanFccId] => 2AANYER815NRQ3 [title] => SGS Appendix B.6: LTE Band 12 Test Report Summary [description] => A summary of the LTE Band 12 test report, including radiated power, bandwidth, and frequency stability results. [brand_name] => SGS [keywords] => ["LTE Band 12", "SEWA2309000114RG01", "QPSK", "16QAM", "64QAM", "256QAM"] [intro] =>This document summarizes the test results for LTE Band 12, as detailed in SGS report SEWA2309000114RG01. The report includes data on Effective (Isotropic) Radiated Power Output, Peak-to-Average Ratio (CCDF), 26dB Bandwidth and Occupied Bandwidth, Band Edge compliance, and Conducted Spurious Emission. The tests were conducted by SGS-CSTC Standards Technical Services (Suzhou) Co., Ltd.
The report provides detailed tables of results for various bandwidths (1.4MHz, 3MHz, 5MHz, and 10MHz) and modulations (QPSK, 16QAM, 64QAM, and 256QAM) across different channels and RB configurations. All tests passed the specified limits. The frequency stability test results are also included, showing minimal deviation across varying voltage and temperature conditions.
The document includes graphical representations of the test results, such as CCDF plots, occupied bandwidth plots, and band edge plots. These graphs provide a visual confirmation of the device's compliance with regulatory requirements.
)
Array ( [0] => Array ( [id] => 8061400 [file_sha256] => [applicationId] => lG6741aoZEILPFyetDX+OQ== [description] => Appendix-B-6-6907754 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => Test Report [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4415708 [submissionDate] => 2025-02-20 00:00:00 [dateAvailable] => 2025-02-21 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2AANY-ER815NRQ3 [cleanFccId] => 2AANYER815NRQ3 [exif] => 0 ) [1] => Array ( [id] => 6907754 [file_sha256] => [applicationId] => 5ntVTe/yZx91SOisSjlnXQ== [description] => Appendix_B.6 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => Test Report [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4415708 [submissionDate] => 2023-11-09 00:00:00 [dateAvailable] => 2023-11-10 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 0 [source] => 0 [fccId] => XMR2023RM520NGL [cleanFccId] => XMR2023RM520NGL [exif] => 0 ) )