System Check Results for D750V3, D835V2, D1900V2, D2450V2, D2600V2, D3500V2, D3700V2, D3900V2, D5GHzV2

IHDT56AV4_Part 1_SAR_Appendix A

This document presents a comprehensive overview of system check results conducted across a range of frequencies, utilizing various Device Under Test (DUT) models. The system checks were performed using the DASY6 configuration, employing specific probes, electronics, and phantom setups to ensure accurate measurements. The report details the Communication System, frequency, and duty cycle used for each check, along with the head simulating liquid medium parameters, including conductivity (σ) and relative permittivity (εr). Ambient and liquid temperatures were carefully monitored and recorded.

Key metrics such as SAR (Specific Absorption Rate) values for 1g and 10g of tissue are presented, derived from both Area Scans and Zoom Scans. Power drift, smallest distance from peaks, and the ratio of SAR at M2 to SAR at M1 are also included to provide a thorough assessment of the system's performance. The system checks cover frequencies including 750MHz, 835MHz, 1900MHz, 2450MHz, 2600MHz, 3500MHz, 3700MHz, 3900MHz, 5250MHz, 5600MHz, and 5750MHz, ensuring a wide spectrum of evaluation. The DUT models tested include D750V3, D835V2, D1900V2, D2450V2, D2600V2, D3500V2, D3700V2, D3900V2, and D5GHzV2.


File Info : application/pdf, 15 Pages, 1.31MB

Download

N/A: D750V3, SN1099, D835V2, SN4d162, D1900V2, SN5d182, D2450V2, SN1095, D2600V2, SN1112, D3500V2, SN1037, D3700V2, SN1008, D3900V2, SN1048, D5GHzV2, SN1113