This document contains calibration reports for the COMOSAR E-field probe and SAR reference dipole. The E-field probe calibration report details measurement uncertainty, sensitivity in air and liquid, linearity, and isotropy. It adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, providing an expanded uncertainty expressed at approximately the 95% confidence level. Calibration measurement results include liquid temperature, lab temperature, and humidity.
The SAR reference dipole calibration report summarizes requirements set forth by IEEE 1528, FCC KDBS, and CEI/IEC 62209 standards for reference dipoles used for SAR measurement system validations. It verifies that the product complies with these standards, covering return loss requirements, mechanical requirements, and measurement uncertainty. The report includes calibration measurement results for return loss and impedance in head and body liquid, mechanical dimensions, and validation measurements with head and body liquid. The dipole operates at 450 MHz and has serial number SN 38/18 DIP 0G450-465.
Array ( [0] => Array ( [url_sha] => 537c0e958e66c6e617a41d48b833e1860a7403cb0b0c79281a36a67cfc9b1a77 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8101601 [href_text] => Test Report SAR2 [href_description] => Xiaowei Communication Technology (Shenzhen) Co., Ltd. GU1 Holding a walkie-talkie 2BAS7-GU1 2BAS7GU1 gu1 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8101601 [http_size] => 4992738 [file_sha256] => f48083c02ac2e0d27c397b7b09b4218b42fb601039ddd54cc1c45b678c0fb244 [domain] => document.fccid ) ) Array ( [file_sha256] => f48083c02ac2e0d27c397b7b09b4218b42fb601039ddd54cc1c45b678c0fb244 [cleanFccId] => 2BAS7GU1 [title] => COMOSAR E-Field Probe and SAR Reference Dipole Calibration Report [description] => Calibration reports for the COMOSAR E-field probe and SAR reference dipole, detailing measurement uncertainty and sensitivity in liquid. [brand_name] => MVG [keywords] => ["IEC/IEEE 62209-1528", "FCC KDB865664 D01", "ACR.180.4.42.BES.A", "SID450", "SN 38/18 DIP 0G450-465", "IEEE 1528", "FCC KDBS", "CEI/IEC 62209"] [intro] =>This document contains calibration reports for the COMOSAR E-field probe and SAR reference dipole. The E-field probe calibration report details measurement uncertainty, sensitivity in air and liquid, linearity, and isotropy. It adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, providing an expanded uncertainty expressed at approximately the 95% confidence level. Calibration measurement results include liquid temperature, lab temperature, and humidity.
The SAR reference dipole calibration report summarizes requirements set forth by IEEE 1528, FCC KDBS, and CEI/IEC 62209 standards for reference dipoles used for SAR measurement system validations. It verifies that the product complies with these standards, covering return loss requirements, mechanical requirements, and measurement uncertainty. The report includes calibration measurement results for return loss and impedance in head and body liquid, mechanical dimensions, and validation measurements with head and body liquid. The dipole operates at 450 MHz and has serial number SN 38/18 DIP 0G450-465.
)
Array ( [0] => Array ( [id] => 8101601 [file_sha256] => [applicationId] => n5pBP6VYF+v/ZuXEwbmqAQ== [description] => Test Report SAR2 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4992740 [submissionDate] => 2025-03-07 00:00:00 [dateAvailable] => 2025-03-07 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2BAS7-GU1 [cleanFccId] => 2BAS7GU1 [exif] => 0 ) )