NTEK Conducted Output Power and Peak-to-Average Ratio Test Report

Attachment for 4G 1-110

This document presents a comprehensive test report detailing the conducted output power and peak-to-average ratio (PAR) measurements for various frequency bands and configurations. The tests were conducted by NTEK, and the report is identified by the number S25022002906006. The report includes detailed tables of results for different bandwidths, UL channels, RB sizes, RB positions, and modulation schemes (QPSK and 16QAM).

The tests cover a wide range of frequency bands, including Band12, Band13, Band17, Band2, Band25, Band26 (814-824 MHz and 824-849 MHz), Band4, Band41, Band5, Band66, and Band7. The report provides specific power measurements in dBm for each configuration, along with a verdict indicating whether the results passed the required limits. The document also includes peak-to-average ratio measurements, ensuring compliance with regulatory requirements.

The report is accredited under Certificate #4298.01, indicating adherence to recognized testing standards. The data presented in this report is crucial for verifying the compliance of wireless devices with regulatory limits on conducted output power and peak-to-average ratio, ensuring proper operation and minimizing interference with other wireless systems.


File Info : application/pdf, 110 Pages, 5.55MB

Download

tags: ["S25022002906006", "4G", "Conducted Output Power", "Peak-to-Average Ratio", "Certificate #4298.01", "Band12", "Band13", "Band17", "Band2", "Band25", "Band26(814-824)", "Band26(824-849)", "Band4", "Band41", "Band5", "Band66", "Band7"]
Array
(
    [0] => Array
        (
            [url_sha] => b1771e58fff24886a4fe7534ea5080e24c5d7eeed60770c2b4be44c325f1f3db
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8266825
            [href_text] => Attachment for 4G 1-110
            [href_description] => SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 25157 Smart Phone 2ANMU-25157 2ANMU25157 25157
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8266825
            [http_size] => 5817960
            [file_sha256] => ee9a4cc67a852c87c7a4a6d8a9db26de5406a8b502b40ff441611b63b6719880
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => ee9a4cc67a852c87c7a4a6d8a9db26de5406a8b502b40ff441611b63b6719880
    [cleanFccId] => 2ANMU25157
    [title] => NTEK Conducted Output Power and Peak-to-Average Ratio Test Report
    [description] => This report details conducted output power and peak-to-average ratio tests, including results and certification information.
    [brand_name] => NTEK
    [keywords] => ["S25022002906006", "4G", "Conducted Output Power", "Peak-to-Average Ratio", "Certificate #4298.01", "Band12", "Band13", "Band17", "Band2", "Band25", "Band26(814-824)", "Band26(824-849)", "Band4", "Band41", "Band5", "Band66", "Band7"]
    [intro] => 

This document presents a comprehensive test report detailing the conducted output power and peak-to-average ratio (PAR) measurements for various frequency bands and configurations. The tests were conducted by NTEK, and the report is identified by the number S25022002906006. The report includes detailed tables of results for different bandwidths, UL channels, RB sizes, RB positions, and modulation schemes (QPSK and 16QAM).

The tests cover a wide range of frequency bands, including Band12, Band13, Band17, Band2, Band25, Band26 (814-824 MHz and 824-849 MHz), Band4, Band41, Band5, Band66, and Band7. The report provides specific power measurements in dBm for each configuration, along with a verdict indicating whether the results passed the required limits. The document also includes peak-to-average ratio measurements, ensuring compliance with regulatory requirements.

The report is accredited under Certificate #4298.01, indicating adherence to recognized testing standards. The data presented in this report is crucial for verifying the compliance of wireless devices with regulatory limits on conducted output power and peak-to-average ratio, ensuring proper operation and minimizing interference with other wireless systems.

)
Array
(
    [0] => Array
        (
            [id] => 8266825
            [file_sha256] => 
            [applicationId] => bABgKKSjblipIyFTdZ306Q==
            [description] => Attachment for 4G 1-110
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => Test Report
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 5817962
            [submissionDate] => 2025-05-07 00:00:00
            [dateAvailable] => 2025-05-07 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2ANMU-25157
            [cleanFccId] => 2ANMU25157
            [exif] => 0
        )

)