This document presents an RF exposure evaluation conducted by Bay Area Compliance Laboratories Corp. to assess compliance with Federal Communications Commission (FCC) guidelines and safety standards. The evaluation focuses on Maximum Permissible Exposure (MPE) limits, ensuring that the public is not exposed to excessive levels of radio frequency energy.
The report references subpart 15.247(i) and subpart 2.1091 of FCC regulations, as well as KDB 447498 D04 Interim General RF Exposure Guidance. It utilizes MPE-based exemption criteria, considering frequency and separation distance to determine effective radiated power (ERP) thresholds. These thresholds are derived from Table B.1 [Table 1 of § 1.1307(b)(3)(i)(C)] for single RF sources operating between 300 kHz and 100 GHz.
The evaluation includes specific data for WIFI operation within the 2412-2472 MHz frequency range, detailing conducted power, antenna gain, ERP levels, and evaluation distance. The results demonstrate compliance with the FCC's RF exposure guidelines, indicating that the equipment should be placed at least 20cm from nearby persons to maintain safety. The final result of the evaluation is 'Compliant'.
Array ( [0] => Array ( [url_sha] => b5a669721f5d6d541b5a01f143e27725889391111682ec029a1bd0c540a72cf8 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8064342 [href_text] => RF Exposure - WIFI [href_description] => Shenzhen Xin Yuan Electronic Technology Co., Ltd. T-MINIE-PAPER Mini E-Paper-S3 2ASYE-T-MINIE-PAPER 2ASYETMINIEPAPER t minie paper [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8064342 [http_size] => 183125 [file_sha256] => ed2de7d34870c947b096b59c49f56c0987d74653f9e28a412ac53056a997c89d [domain] => document.fccid ) ) Array ( [file_sha256] => ed2de7d34870c947b096b59c49f56c0987d74653f9e28a412ac53056a997c89d [cleanFccId] => 2ASYETMINIEPAPER [title] => RF Exposure Evaluation: Ensuring Compliance and Safety [description] => This report evaluates RF exposure to ensure compliance with FCC guidelines and safety standards, focusing on permissible exposure limits for WIFI. [brand_name] => Bay Area Compliance Laboratories Corp. [keywords] => ["RF Exposure", "MPE", "FCC", "WIFI", "2401Y22088E-RF-00B"] [intro] =>This document presents an RF exposure evaluation conducted by Bay Area Compliance Laboratories Corp. to assess compliance with Federal Communications Commission (FCC) guidelines and safety standards. The evaluation focuses on Maximum Permissible Exposure (MPE) limits, ensuring that the public is not exposed to excessive levels of radio frequency energy.
The report references subpart 15.247(i) and subpart 2.1091 of FCC regulations, as well as KDB 447498 D04 Interim General RF Exposure Guidance. It utilizes MPE-based exemption criteria, considering frequency and separation distance to determine effective radiated power (ERP) thresholds. These thresholds are derived from Table B.1 [Table 1 of § 1.1307(b)(3)(i)(C)] for single RF sources operating between 300 kHz and 100 GHz.
The evaluation includes specific data for WIFI operation within the 2412-2472 MHz frequency range, detailing conducted power, antenna gain, ERP levels, and evaluation distance. The results demonstrate compliance with the FCC's RF exposure guidelines, indicating that the equipment should be placed at least 20cm from nearby persons to maintain safety. The final result of the evaluation is 'Compliant'.
)
Array ( [0] => Array ( [id] => 8064342 [file_sha256] => [applicationId] => tYQg/Y7OPax/veDMu/mnXA== [description] => RF Exposure - WIFI [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 183127 [submissionDate] => 2025-02-21 00:00:00 [dateAvailable] => 2025-02-21 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2ASYE-T-MINIE-PAPER [cleanFccId] => 2ASYETMINIEPAPER [exif] => 0 ) )