SAR Test Report: 2.4GWIFI - EMTEK Co., Ltd. - 2024/12/30

SAR test report appendix B

This document presents the Specific Absorption Rate (SAR) test report for the 2.4GWIFI device, conducted by Shenzhen EMTEK Co., Ltd. on December 30, 2024. The report details the testing methodology, equipment configuration, and results obtained during the SAR assessment.

The device was tested under the 802.11b communication standard at a frequency of 2437 MHz with a duty cycle of 1:1. The testing environment utilized H2450 medium parameters, with a conductivity (σ) of 1.79 S/m and a relative permittivity (εr) of 40.18. The ambient and liquid temperatures were maintained at 22.3°C and 22.1°C, respectively.

The DASY5 configuration included the EX3DV4 probe (SN3970), calibrated on June 25, 2024, and the DAE4 electronics (Sn1418), calibrated on May 17, 2024. The ELI v5.0 phantom (QDOVA002AA, Serial: TP:1231) was used for the tests. The measurement software employed was DASY52, Version 52.8 (7), with SEMCAD X Version 14.6.10 (7164).

The Front/Area Scan (8x11x1) yielded a maximum SAR value of 0.382 W/kg. The Front/Zoom Scan (5x5x7)/Cube 0 analysis resulted in a SAR(1 g) of 0.265 W/kg and a SAR(10 g) of 0.123 W/kg, with a maximum SAR value of 0.362 W/kg.


File Info : application/pdf, 1 Pages, 108.00KB

Download
Acrobat Distiller 15.0 (Windows)
tags: ["2.4GWIFI", "EX3DV4 - SN3970", "DAE4 Sn1418", "QDOVA002AA", "TP:1231", "DASY52", "SEMCAD X Version 14.6.10 (7164)"]
Array
(
    [0] => Array
        (
            [url_sha] => 8afca184dd7cc5a9c04e3cc4bb5f08d6bb71717b7b8f82d72868d60f9f27310c
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8086450
            [href_text] => SAR test report appendix B
            [href_description] => UNI-TREND TECHNOLOGY (CHINA) CO., LTD. 3841218MR Thermal Monocular with Rangefinder 2APMK-3841218MR 2APMK3841218MR 3841218mr
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8086450
            [http_size] => 110597
            [file_sha256] => eb6f9d826e892647dd470d6e82a5648943343a2de2e254c007dd1e14b2b44813
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => eb6f9d826e892647dd470d6e82a5648943343a2de2e254c007dd1e14b2b44813
    [cleanFccId] => 2APMK3841218MR
    [title] => SAR Test Report: 2.4GWIFI - EMTEK Co., Ltd. - 2024/12/30
    [description] => SAR compliance test report for the 2.4GWIFI device, detailing measurements and configurations. Includes DASY5 setup and results.
    [brand_name] => EMTEK
    [keywords] => ["2.4GWIFI", "EX3DV4 - SN3970", "DAE4 Sn1418", "QDOVA002AA", "TP:1231", "DASY52", "SEMCAD X Version 14.6.10 (7164)"]
    [intro] => 

This document presents the Specific Absorption Rate (SAR) test report for the 2.4GWIFI device, conducted by Shenzhen EMTEK Co., Ltd. on December 30, 2024. The report details the testing methodology, equipment configuration, and results obtained during the SAR assessment.

The device was tested under the 802.11b communication standard at a frequency of 2437 MHz with a duty cycle of 1:1. The testing environment utilized H2450 medium parameters, with a conductivity (σ) of 1.79 S/m and a relative permittivity (εr) of 40.18. The ambient and liquid temperatures were maintained at 22.3°C and 22.1°C, respectively.

The DASY5 configuration included the EX3DV4 probe (SN3970), calibrated on June 25, 2024, and the DAE4 electronics (Sn1418), calibrated on May 17, 2024. The ELI v5.0 phantom (QDOVA002AA, Serial: TP:1231) was used for the tests. The measurement software employed was DASY52, Version 52.8 (7), with SEMCAD X Version 14.6.10 (7164).

The Front/Area Scan (8x11x1) yielded a maximum SAR value of 0.382 W/kg. The Front/Zoom Scan (5x5x7)/Cube 0 analysis resulted in a SAR(1 g) of 0.265 W/kg and a SAR(10 g) of 0.123 W/kg, with a maximum SAR value of 0.362 W/kg.

)
Array
(
    [0] => Array
        (
            [id] => 8086450
            [file_sha256] => 
            [applicationId] => euMETfA1FHJyLl5pI15ylg==
            [description] => SAR test report appendix B
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 110599
            [submissionDate] => 2025-03-03 00:00:00
            [dateAvailable] => 2025-03-03 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2APMK-3841218MR
            [cleanFccId] => 2APMK3841218MR
            [exif] => 0
        )

)