This document presents a comprehensive set of calibration reports, phantom certificates, and system check information relevant to Specific Absorption Rate (SAR) testing conducted by Cetecom Advanced GmbH. The annex includes calibration details for various probes, specifically the EX3DV4 models with serial numbers SN:7566 and SN:7852. It also encompasses calibration reports for system validation dipoles operating at 750 MHz (D750V3-SN:1041), 835 MHz (D835V2-SN:4d153), 1750 MHz (D1750V2-SN:1093), and 1900 MHz (D1900V2-SN:5d009).
Furthermore, the document provides calibration certificates for Data Acquisition Units (DAE) with serial numbers SN:1387 and DAE4ip-SN:1842, along with certificates of conformity for SAM Twin Phantoms (V4.0, V5.0, and V8.0) and the ELI Phantom V8.0. The document adheres to the standards set by DIN EN ISO/IEC 17025 (2018-03) and is accredited by the Deutsche Akkreditierungsstelle GmbH (DAkkS) under registration number D-PL-12047-01-00. The testing laboratory is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate starting with the registration number: D-PL-12047-01-00.
Array ( [0] => Array ( [url_sha] => 23f9f367f862dac3514ca72dd45554ca049d8ec03d8b597958d65a2c44685f80 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8307533 [href_text] => QRI-CMSMART4GWW2_SAR Calibr [href_description] => BIOTRONIK SE & Co. KG CMSMART4GWW2 CardioMessenger Smart / Telemonitoring System QRI-CMSMART4GWW2 QRICMSMART4GWW2 cmsmart4gww2 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8307533 [http_size] => 4322294 [file_sha256] => e2b3f7ce4d798e00c2d04a60a08477fb35399ef571469651971ab542e580c004 [domain] => document.fccid ) [1] => Array ( [url_sha] => d0788962cb96f0fe3c7cfcf583bd993724277d9c0dc07f06d53bb974aa1515f1 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8307558 [href_text] => QRI-CMSMART4GWW2_SAR Calibr [href_description] => BIOTRONIK SE & Co. KG CMSMART4GWW2 CardioMessenger Smart / Telemonitoring System QRI-CMSMART4GWW2 QRICMSMART4GWW2 cmsmart4gww2 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8307558 [http_size] => 4322294 [file_sha256] => e2b3f7ce4d798e00c2d04a60a08477fb35399ef571469651971ab542e580c004 [domain] => document.fccid ) ) Array ( [file_sha256] => e2b3f7ce4d798e00c2d04a60a08477fb35399ef571469651971ab542e580c004 [cleanFccId] => QRICMSMART4GWW2 [title] => SAR Calibration Report: Cetecom Advanced GmbH [description] => This document contains calibration data, phantom certificates, and system check information for Cetecom Advanced GmbH's SAR testing. [brand_name] => Cetecom Advanced [keywords] => ["EX3DV4", "SN:7566", "SN:7852", "D750V3", "SN:1041", "D835V2", "SN:4d153", "D1750V2", "SN:1093", "D1900V2", "SN:5d009", "DAE", "SN:1387", "DAE4ip", "SN:1842", "SAM Twin Phantom V4.0", "V5.0", "V8.0", "ELI Phantom V8.0", "DIN EN ISO/IEC 17025", "2018-03", "D-PL-12047-01-00", "SCS 0108"] [intro] =>This document presents a comprehensive set of calibration reports, phantom certificates, and system check information relevant to Specific Absorption Rate (SAR) testing conducted by Cetecom Advanced GmbH. The annex includes calibration details for various probes, specifically the EX3DV4 models with serial numbers SN:7566 and SN:7852. It also encompasses calibration reports for system validation dipoles operating at 750 MHz (D750V3-SN:1041), 835 MHz (D835V2-SN:4d153), 1750 MHz (D1750V2-SN:1093), and 1900 MHz (D1900V2-SN:5d009).
Furthermore, the document provides calibration certificates for Data Acquisition Units (DAE) with serial numbers SN:1387 and DAE4ip-SN:1842, along with certificates of conformity for SAM Twin Phantoms (V4.0, V5.0, and V8.0) and the ELI Phantom V8.0. The document adheres to the standards set by DIN EN ISO/IEC 17025 (2018-03) and is accredited by the Deutsche Akkreditierungsstelle GmbH (DAkkS) under registration number D-PL-12047-01-00. The testing laboratory is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate starting with the registration number: D-PL-12047-01-00.
)
Array ( [0] => Array ( [id] => 8307533 [file_sha256] => [applicationId] => nocjR0XW2TYSnT3Sk6XeSg== [description] => QRI-CMSMART4GWW2_SAR Calibr [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4322294 [submissionDate] => 2025-05-20 00:00:00 [dateAvailable] => 2025-05-20 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => QRI-CMSMART4GWW2 [cleanFccId] => QRICMSMART4GWW2 [exif] => 0 ) )