This document presents the RF Exposure Evaluation Report for the Powerflex System Inc. Electric Vehicle AC Charger, model PF-96D. The report, identified by reference number MTEB24110233-H and FCC ID 2A6G9-ACEVC48DW, assesses the device's compliance with RF exposure limits as outlined in 47 CFR Part 1.1307 and 1.1310, and KDB447498D01. The evaluation considers standalone SAR test exclusion and maximum permissible exposure (MPE) limits.
The report details the test setup, including the operating frequency of 13.56MHz and modulation type ASK. It includes calculations based on the Friis transmission formula to determine power density at a specified distance. The results indicate that the device meets the required RF exposure limits, ensuring safe operation for users. The report also includes collocated power density calculations for simultaneous transmission scenarios with Bluetooth and Wi-Fi, confirming compliance with FCC regulations.
Array ( [0] => Array ( [url_sha] => dec459a145852c55b9d087a2dbe17fc3288d812acded09df7ca4f57f0c42a083 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8106383 [href_text] => RF Exposure Info [href_description] => powerflex systems inc ACEVC48DW Electric Vehicle AC Charger 2A6G9-ACEVC48DW 2A6G9ACEVC48DW acevc48dw [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8106383 [http_size] => 351050 [file_sha256] => e1109b08fbde03732f68414d80a4955e777a912ba90977caa248831849e79125 [domain] => document.fccid ) ) Array ( [file_sha256] => e1109b08fbde03732f68414d80a4955e777a912ba90977caa248831849e79125 [cleanFccId] => 2A6G9ACEVC48DW [title] => Powerflex System Inc. RF Exposure Evaluation Report [description] => This report evaluates the RF exposure of the Powerflex System Inc. Electric Vehicle AC Charger, ensuring compliance with FCC standards. [brand_name] => Powerflex System Inc [keywords] => ["MTEB24110233-H", "2A6G9-ACEVC48DW", "PF-96D", "Electric Vehicle AC Charger"] [intro] =>This document presents the RF Exposure Evaluation Report for the Powerflex System Inc. Electric Vehicle AC Charger, model PF-96D. The report, identified by reference number MTEB24110233-H and FCC ID 2A6G9-ACEVC48DW, assesses the device's compliance with RF exposure limits as outlined in 47 CFR Part 1.1307 and 1.1310, and KDB447498D01. The evaluation considers standalone SAR test exclusion and maximum permissible exposure (MPE) limits.
The report details the test setup, including the operating frequency of 13.56MHz and modulation type ASK. It includes calculations based on the Friis transmission formula to determine power density at a specified distance. The results indicate that the device meets the required RF exposure limits, ensuring safe operation for users. The report also includes collocated power density calculations for simultaneous transmission scenarios with Bluetooth and Wi-Fi, confirming compliance with FCC regulations.
)
Array ( [0] => Array ( [id] => 8106383 [file_sha256] => [applicationId] => dx77Wrtc6X/3l3+I4UXkoA== [description] => RF Exposure Info [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 351051 [submissionDate] => 2025-03-10 00:00:00 [dateAvailable] => 2025-03-10 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2A6G9-ACEVC48DW [cleanFccId] => 2A6G9ACEVC48DW [exif] => 0 ) )