This document presents the FCC Part 96 test report for the AmpliTech Group's Low Power Radio Unit (LPRU), model AMPU-LPRU-Gen3-3537-AE-AI, FCC ID: 2BNMP-AMPU-LPRU. Conducted by AA Electro Magnetic Test Laboratory Private Limited, the report details various tests performed to ensure compliance with FCC regulations. The tests include Equivalent Isotropic Radiated Power (EIRP) measurements, frequency stability assessments, occupied bandwidth evaluations, peak-to-average ratio analysis, and conducted/radiated spurious emissions testing.
The test results indicate that the equipment under test (EUT) meets the FCC requirements. The report provides detailed information on the test setup, procedures, and results for each test performed. It also includes a list of equipment used during testing and relevant certifications. The declaration of conformity confirms that the results align with the standard limits. The document serves as evidence of the LPRU's adherence to regulatory standards, ensuring its suitability for operation within the specified frequency bands.
The report is applicable only to the tested sample and should not be used to claim product endorsement by any U.S. government agency. The testing was conducted between December 24, 2024, and February 20, 2025, with the report issued on May 02, 2025.