EX3DV4 Calibration Report: Probe Parameters and Modulation

Part 1_SAR_Appendix C_Part3-3

This document presents the calibration report for the EX3DV4 probe, serial number SN:7576. The calibration was performed by Schmid & Partner Engineering AG, an accredited Swiss Calibration Service (SCS 0108). The report details the probe's parameters, including sensitivity in free space and tissue simulating liquid (TSL), diode compression point (DCP), and modulation dependent linearization parameters. Calibration is performed according to IEC/IEEE 62209-1528 and KDB 865664 standards.

The report includes a glossary of terms, calibration results for modulation response, sensor model parameters, and other probe parameters such as sensor arrangement and connector angle. Calibration parameters are determined in head tissue simulating media for various frequencies. Frequency validity and uncertainty are also specified. The document includes frequency response charts, receiving patterns, dynamic range assessments, conversion factor assessments, and deviation from isotropy in liquid.

Appendix C provides modulation calibration parameters for a wide range of communication systems, including CW, pulse waveforms, QPSK, 64-QAM, WLAN, LTE-FDD, LTE-TDD, and 5G NR. The uncertainty of measurement is stated as the standard uncertainty multiplied by the coverage factor k=2.


File Info : application/pdf, 21 Pages, 4.24MB

Download
福昕风腾PDF套件 打印机版本 7.3.4.0308
Schmid & Partner Engineering AG: EX3DV4, SN:7576, SCS 0108, FA521816, DASY, Calibration, Probe