Liberty Defense Technologies HW2000 Emissions Test Report

Test Report

This report details the emissions testing performed on the Liberty Defense Technologies Hexwave HW2000 security body scanner. The testing was conducted to ensure compliance with FCC Part 15, Subpart F, §15.511, FCC Waver DA-22-133A1-c3, RSS-220 Issue 1 (March 2009) Amendment 1 (July 2018), and RSS-GEN Issue 5 April 2018 +Amendment 1 (March 2019) +Amendment 2 (February 2021) standards. The report outlines the scope of work, test methodology, equipment used, and results obtained during the investigation.

The HW2000 is a UWB device designed for threat detection imaging, operating in the 6-10.6 GHz band. The system sweeps through its frequency range in 200-megahertz blocks, utilizing a continuous waveform signal. The report includes measurements of fundamental emissions, operational bandwidth, and unwanted emissions, demonstrating compliance with the specified limits. The test setup and configurations are documented with photographs, and the results are presented in both tabular and graphical formats. The sample tested was found to comply with all applicable standards.


File Info : application/pdf, 39 Pages, 2.62MB

Download
Microsoft Word for Microsoft 365
Liberty Defense Technologies: HW2000, Hexwave, 105998912BOX-006, FCC Part 15, RSS-220, DA-22-133A1-c3