This document presents a comprehensive SAR (Specific Absorption Rate) test report, detailing Measurement 10 and associated calibration certificates. The report includes experimental conditions, SAR measurement results, and calibration data for various equipment used during the testing process. Key aspects covered include area scans, zoom scans, phantom specifications, device positioning, and signal characteristics.
The report also provides detailed information on the SAR measurement results, including frequency, relative permittivity (real and imaginary parts), conductivity, and variation. Surface and volume SAR visualizations are presented, along with maximum location and SAR peak values. Calibration certificates for E-field probes and dipoles are included, covering a range of frequencies from 750 MHz to 2600 MHz. The calibration process adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring traceability to national metrology institutions. The report also includes a list of equipment used during the testing process, along with their calibration dates and identification numbers.
The calibration certificates detail the methods and results from accredited COMOSAR E-Field Probe and SAR reference dipole calibrations performed at MVG. The calibration results are traceable to the International System of Units (SI). The report includes information on linearity, sensitivity, isotropy, and boundary effects. Measurement uncertainties are also addressed, providing a comprehensive overview of the accuracy and reliability of the SAR testing process.
Array ( [0] => Array ( [url_sha] => 7c1ee0a2c2315b70fb29ddb06c8a20a25a7fc4977c0be5e3b46ac78ef0852e9e [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8086781 [href_text] => SAR Test Report 2 [href_description] => Trackimo INC. TRKM010-C Tracki 4G 2AAI6-TRKM010-C 2AAI6TRKM010C trkm010 c [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8086781 [http_size] => 5195404 [file_sha256] => cb3a466b7d1959142c0a6580fef6e44d8827ba63a02444d6387aa53f978c9050 [domain] => document.fccid ) [1] => Array ( [url_sha] => 09f90acf1747e2fbe6ea382c7e8ac5f6803c97ee217744ed2d43508aa617594a [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8086521 [href_text] => SAR Test report 2 [href_description] => Trackimo INC. TRKM010-C Tracki 4G 2AAI6-TRKM010-C 2AAI6TRKM010C trkm010 c [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8086521 [http_size] => 5195404 [file_sha256] => cb3a466b7d1959142c0a6580fef6e44d8827ba63a02444d6387aa53f978c9050 [domain] => document.fccid ) ) Array ( [file_sha256] => cb3a466b7d1959142c0a6580fef6e44d8827ba63a02444d6387aa53f978c9050 [cleanFccId] => 2AAI6TRKM010C [title] => AIT SAR Test Report: Measurement 10 & Calibration [description] => This report details SAR measurements, experimental conditions, and calibration results for AIT's testing, including equipment lists. [brand_name] => AIT [keywords] => ["LTEBand26", "EPGO0523-403", "DIP 0G750-355", "DIP 0G835-347", "DIP 1G800-349", "DIP 1G900-350", "DIP 2G450-352", "DIP 2G600-356", "AITSZ24061413FW4", "IEC/IEEE 62209-1528", "FCC KDB865664 D01", "SN 39/21 EPG00523-403", "SID750", "SN 03/15 DIP0G750-355", "SID835", "SN 03/15 DIP0G835-347", "ACR.307.3.24.BES.A", "ACR.53.23.24.BES.A", "ACR.53.24.24.BES.A"] [intro] =>This document presents a comprehensive SAR (Specific Absorption Rate) test report, detailing Measurement 10 and associated calibration certificates. The report includes experimental conditions, SAR measurement results, and calibration data for various equipment used during the testing process. Key aspects covered include area scans, zoom scans, phantom specifications, device positioning, and signal characteristics.
The report also provides detailed information on the SAR measurement results, including frequency, relative permittivity (real and imaginary parts), conductivity, and variation. Surface and volume SAR visualizations are presented, along with maximum location and SAR peak values. Calibration certificates for E-field probes and dipoles are included, covering a range of frequencies from 750 MHz to 2600 MHz. The calibration process adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring traceability to national metrology institutions. The report also includes a list of equipment used during the testing process, along with their calibration dates and identification numbers.
The calibration certificates detail the methods and results from accredited COMOSAR E-Field Probe and SAR reference dipole calibrations performed at MVG. The calibration results are traceable to the International System of Units (SI). The report includes information on linearity, sensitivity, isotropy, and boundary effects. Measurement uncertainties are also addressed, providing a comprehensive overview of the accuracy and reliability of the SAR testing process.
)
Array ( [0] => Array ( [id] => 8086521 [file_sha256] => [applicationId] => DH2mWVSe5hzP1nWLgDqvtQ== [description] => SAR Test report 2 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 5195406 [submissionDate] => 2025-03-03 00:00:00 [dateAvailable] => 2025-03-03 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2AAI6-TRKM010-C [cleanFccId] => 2AAI6TRKM010C [exif] => 0 ) )