This document is a Specific Absorption Rate (SAR) test report for the MK-LR Handheld Thermal Imaging Monocular, manufactured by Chengdu Jingpin Night Vision Optoelectronics Technology Co., Ltd. The report, identified by number LCSA11184073EB, details the SAR testing procedures and results conducted to ensure compliance with FCC regulations and safety standards.

The device was tested in accordance with FCC 47CFR §2.1093, ANSI/IEEE C95.1-2019, and IEEE 1528-2013 standards. The maximum SAR value reported for the device is 0.473 W/kg, indicating compliance with the general population/uncontrolled exposure limits. The report includes detailed information on the test setup, equipment used, tissue simulating liquid composition, and measurement results.

The testing was performed by Shenzhen LCS Compliance Testing Laboratory Ltd. The report provides a comprehensive overview of the SAR assessment, including system verification, measurement procedures, and uncertainty analysis. Calibration certificates for the testing equipment are also included in the appendix.


File Info : application/pdf, 47 Pages, 5.45MB

Download
福昕高级PDF编辑器打印机版本8.0.2.0718
tags: ["MK-LR", "Handheld Thermal Imaging Monocular", "2BEDO-MK-LR", "LCSA11184073EB"]
Array
(
    [0] => Array
        (
            [url_sha] => 84635e8ed2877b15628997de9a431ff263938c409e9c4476762a9fe29db9ca69
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8065446
            [href_text] => SAR Report part 1
            [href_description] => Chengdu Jingpin Night Vision Optoelectronics Technology Co., Ltd. MK-LR Handheld Thermal Imaging Monocular (with laser ranging) 2BEDO-MK-LR 2BEDOMKLR mk lr
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8065446
            [http_size] => 5710300
            [file_sha256] => c847d766086a8fb348d6a1abc04785cc6c451608a793e1b481867d8e422a1194
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => c847d766086a8fb348d6a1abc04785cc6c451608a793e1b481867d8e422a1194
    [cleanFccId] => 2BEDOMKLR
    [title] => SAR Test Report for Chengdu Jingpin Night Vision MK-LR Monocular
    [description] => SAR test report for the Chengdu Jingpin Night Vision Optoelectronics Technology Co., Ltd. MK-LR Monocular, FCC ID: 2BEDO-MK-LR, LCSA11184073EB.
    [brand_name] => Chengdu Jingpin Night Vision
    [keywords] => ["MK-LR", "Handheld Thermal Imaging Monocular", "2BEDO-MK-LR", "LCSA11184073EB"]
    [intro] => 
  

This document is a Specific Absorption Rate (SAR) test report for the MK-LR Handheld Thermal Imaging Monocular, manufactured by Chengdu Jingpin Night Vision Optoelectronics Technology Co., Ltd. The report, identified by number LCSA11184073EB, details the SAR testing procedures and results conducted to ensure compliance with FCC regulations and safety standards.

The device was tested in accordance with FCC 47CFR §2.1093, ANSI/IEEE C95.1-2019, and IEEE 1528-2013 standards. The maximum SAR value reported for the device is 0.473 W/kg, indicating compliance with the general population/uncontrolled exposure limits. The report includes detailed information on the test setup, equipment used, tissue simulating liquid composition, and measurement results.

The testing was performed by Shenzhen LCS Compliance Testing Laboratory Ltd. The report provides a comprehensive overview of the SAR assessment, including system verification, measurement procedures, and uncertainty analysis. Calibration certificates for the testing equipment are also included in the appendix.

)
Array
(
    [0] => Array
        (
            [id] => 8065446
            [file_sha256] => 
            [applicationId] => ea/dq2K1NRh/BXFXPKvusw==
            [description] => SAR Report part 1
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 5710302
            [submissionDate] => 2025-02-24 00:00:00
            [dateAvailable] => 2025-02-24 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2BEDO-MK-LR
            [cleanFccId] => 2BEDOMKLR
            [exif] => 0
        )

)