This document presents the Specific Absorption Rate (SAR) test report for the 5.2GWIFI device, conducted by Shenzhen EMTEK Co.,Ltd. on February 25, 2025. The device was tested according to the 802.11n communication standard at a frequency of 5240 MHz with a duty cycle of 1:1.
The testing environment utilized HSL 5GHz medium with specific parameters (σ = 4.66 S/m; ɛr = 35.91; p = 1000 kg/m³) at an ambient temperature of 22.0 °C and a liquid temperature of 21.8 °C. The DASY5 configuration included the EX3DV4 - SN3970 probe (calibrated on 2024/6/25), DAE4 Sn1418 electronics (calibrated on 2024/5/17), and ELI v5.0 phantom (Type: QDOVA002AA; Serial: TP:1231). The measurement software used was DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164).
The Back High/Area Scan (8x11x1) yielded a maximum SAR value of 1.02 W/kg. The Back High/Zoom Scan (9x9x16)/Cube 0 resulted in a SAR(1 g) of 1.28 W/kg and a SAR(10 g) of 0.388 W/kg, with a maximum SAR value of 2.74 W/kg.
Array ( [0] => Array ( [url_sha] => e048b8d951901be48d2d9ea8bdba2853d5f172a7e5252e86db8d20e74771c61e [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8106263 [href_text] => Appendix B [href_description] => GUANGDONG HENGDI TECHNOLOGY CORP.,LTD. 2024SC SKYVIEW FPV Real-time Video Transmission Drone-Display screen 2AWZK-2024SC 2AWZK2024SC 2024sc [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8106263 [http_size] => 242249 [file_sha256] => c7dd6c134dad7bf6d4eccbef8084316e66c17c76fadf1be0e7c41f8bc80e7b13 [domain] => document.fccid ) ) Array ( [file_sha256] => c7dd6c134dad7bf6d4eccbef8084316e66c17c76fadf1be0e7c41f8bc80e7b13 [cleanFccId] => 2AWZK2024SC [title] => 5.2GWIFI SAR Test Report: Shenzhen EMTEK Co.,Ltd. [description] => Detailed SAR test report for the 5.2GWIFI device, conducted by Shenzhen EMTEK Co.,Ltd. Includes configuration, scan results, and SAR values. [brand_name] => Shenzhen EMTEK Co.,Ltd. [keywords] => ["5.2GWIFI", "EX3DV4 - SN3970", "DAE4 Sn1418", "QDOVA002AA", "ELI v5.0", "802.11n"] [intro] =>This document presents the Specific Absorption Rate (SAR) test report for the 5.2GWIFI device, conducted by Shenzhen EMTEK Co.,Ltd. on February 25, 2025. The device was tested according to the 802.11n communication standard at a frequency of 5240 MHz with a duty cycle of 1:1.
The testing environment utilized HSL 5GHz medium with specific parameters (σ = 4.66 S/m; ɛr = 35.91; p = 1000 kg/m³) at an ambient temperature of 22.0 °C and a liquid temperature of 21.8 °C. The DASY5 configuration included the EX3DV4 - SN3970 probe (calibrated on 2024/6/25), DAE4 Sn1418 electronics (calibrated on 2024/5/17), and ELI v5.0 phantom (Type: QDOVA002AA; Serial: TP:1231). The measurement software used was DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164).
The Back High/Area Scan (8x11x1) yielded a maximum SAR value of 1.02 W/kg. The Back High/Zoom Scan (9x9x16)/Cube 0 resulted in a SAR(1 g) of 1.28 W/kg and a SAR(10 g) of 0.388 W/kg, with a maximum SAR value of 2.74 W/kg.
)
Array ( [0] => Array ( [id] => 8106263 [file_sha256] => [applicationId] => Zx7XkH+KxZRV4IYE29pEWQ== [description] => Appendix B [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => Test Report [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 242251 [submissionDate] => 2025-03-10 00:00:00 [dateAvailable] => 2025-03-10 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2AWZK-2024SC [cleanFccId] => 2AWZK2024SC [exif] => 0 ) )