RF Exposure Requirements and Compliance Report

RF Exposure

This document presents a comprehensive assessment of RF exposure requirements for the GAVIOTA SIMBAC, SL. transmitter. It begins with general information about the client, including the applicant and manufacturer details, both located at AUTOVIA DE ALICANTE A-31, KM 196 03630 SAX SPAIN. The equipment under test (EUT) is identified as a transmitter with model numbers 60090165 and 60090195, operating at a rated voltage of DC 3V and identified by FCC ID 2BLNM-60090165. It is classified as a portable device.

The technical characteristics of the EUT are detailed, including a frequency range of 433.92 MHz and a maximum field strength of 77.11 dBuV/m at 3 meters. The modulation type is FSK, and it utilizes a PCB antenna with 0dBi gain. The report then delves into RF exposure exemption criteria according to FCC rules, specifically referencing sections 1.1307(b)(3) and KDB 447498 D04. It explores various options for exemption, including power thresholds and separation distances.

Finally, the document presents a calculated result of the RF exposure assessment, including the prediction frequency, field strength, antenna gain, output power, and tune-up power. The ERP is calculated, and a ratio is determined to assess compliance with exposure limits. The report concludes with a pass/fail determination, indicating whether the EUT meets the required RF exposure standards.


File Info : application/pdf, 3 Pages, 184.34KB

Download
Microsoft Word 2013 Microsoft Word 2013
tags: ["60090165", "60090195", "2BLNM-60090165", "Transmitter", "RF Exposure"]
Array
(
    [0] => Array
        (
            [url_sha] => 29ed36bcfa720b5f3c547240fa012828c56c1055881f07ceb221b5ebb7e1f8ee
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8077314
            [href_text] => RF Exposure
            [href_description] => GAVIOTA SIMBAC, SL. 60090165 Transmitter 2BLNM-60090165 2BLNM60090165 60090165
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8077314
            [http_size] => 188760
            [file_sha256] => c653044578dd022f63714bf23fa461770fe746e753e8371684f0bade365f1e64
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => c653044578dd022f63714bf23fa461770fe746e753e8371684f0bade365f1e64
    [cleanFccId] => 2BLNM60090165
    [title] => RF Exposure Requirements and Compliance Report
    [description] => This report details the RF exposure requirements and compliance assessment for the GAVIOTA SIMBAC, SL. transmitter, ensuring safety standards are met.
    [brand_name] => GAVIOTA SIMBAC, SL.
    [keywords] => ["60090165", "60090195", "2BLNM-60090165", "Transmitter", "RF Exposure"]
    [intro] => 

This document presents a comprehensive assessment of RF exposure requirements for the GAVIOTA SIMBAC, SL. transmitter. It begins with general information about the client, including the applicant and manufacturer details, both located at AUTOVIA DE ALICANTE A-31, KM 196 03630 SAX SPAIN. The equipment under test (EUT) is identified as a transmitter with model numbers 60090165 and 60090195, operating at a rated voltage of DC 3V and identified by FCC ID 2BLNM-60090165. It is classified as a portable device.

The technical characteristics of the EUT are detailed, including a frequency range of 433.92 MHz and a maximum field strength of 77.11 dBuV/m at 3 meters. The modulation type is FSK, and it utilizes a PCB antenna with 0dBi gain. The report then delves into RF exposure exemption criteria according to FCC rules, specifically referencing sections 1.1307(b)(3) and KDB 447498 D04. It explores various options for exemption, including power thresholds and separation distances.

Finally, the document presents a calculated result of the RF exposure assessment, including the prediction frequency, field strength, antenna gain, output power, and tune-up power. The ERP is calculated, and a ratio is determined to assess compliance with exposure limits. The report concludes with a pass/fail determination, indicating whether the EUT meets the required RF exposure standards.

)
Array
(
    [0] => Array
        (
            [id] => 8077314
            [file_sha256] => 
            [applicationId] => xu3rF5tMS1M+wmSPwkJ1EQ==
            [description] => RF Exposure
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 188760
            [submissionDate] => 2025-02-27 00:00:00
            [dateAvailable] => 2025-02-27 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2BLNM-60090165
            [cleanFccId] => 2BLNM60090165
            [exif] => 0
        )

)