This document contains calibration reports for a COMOSAR Dosimetric E-Field Probe and a COMOSAR Reference Dipole, both manufactured by MVG (Microwave Vision Group). The E-Field Probe calibration, performed on September 18, 2024, details the probe's sensitivity, linearity, and isotropy, ensuring accurate electric field measurements. The probe, model SSE2 with serial number SN 08/21 EPGO352, was calibrated using the CALIPROBE test bench and is intended for use with MVG COMOSAR systems.
The Reference Dipole calibration report, dated July 4, 2023, covers a 2450 MHz dipole with serial number SN 30/14 DIP2G450-335. This report outlines the return loss, impedance, and mechanical dimensions of the dipole, verifying its compliance with IEEE 1528, OET 65 Bulletin C, and CEI/IEC 62209 standards. Validation measurements in both head and body simulating liquids are included, demonstrating the dipole's performance within specified SAR limits. Both calibrations are traceable to international standards, ensuring the reliability of SAR testing results.
Array ( [0] => Array ( [url_sha] => 78e897eb7d5e3d12593c05c8e6aa4c7c0c8709f126cc2e2fbe5189fb2c3eef8f [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8306445 [href_text] => MPE1 [href_description] => XPO Health Limited MIHEALTH02 E4L miHealth 2.0 2BOXK-MIHEALTH02 2BOXKMIHEALTH02 mihealth02 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8306445 [http_size] => 4078245 [file_sha256] => c13abf2908c195e9a079eb2d72939dd44f18e1f8a214f6aa03c7939a9a59f900 [domain] => document.fccid ) [1] => Array ( [url_sha] => 45ca63ef4c878571f1c74768a8b87bb549dbcf5f2404840d598067161fb8e52e [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8306492 [href_text] => MPE1 [href_description] => XPO Health Limited MIHEALTH02 E4L miHealth 2.0 2BOXK-MIHEALTH02 2BOXKMIHEALTH02 mihealth02 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8306492 [http_size] => 4078245 [file_sha256] => c13abf2908c195e9a079eb2d72939dd44f18e1f8a214f6aa03c7939a9a59f900 [domain] => document.fccid ) ) Array ( [file_sha256] => c13abf2908c195e9a079eb2d72939dd44f18e1f8a214f6aa03c7939a9a59f900 [cleanFccId] => 2BOXKMIHEALTH02 [title] => MVG COMOSAR Calibration Reports: E-Field Probe & Dipole [description] => Calibration reports for MVG COMOSAR E-Field Probe and Reference Dipole, ensuring accuracy and traceability to international standards for SAR testing. [brand_name] => MVG (Microwave Vision Group) [keywords] => ["COMOSAR", "E-Field Probe", "Dosimetric E-Field Probe", "Reference Dipole", "SSE2", "SN 08/21 EPGO352", "SN 30/14 DIP2G450-335", "ACR.268.4.24.BES.A", "ACR.262.10.23.MVGB.A", "IEC/IEEE 62209-1528", "FCC KDB865664 D01", "IEEE 1528", "OET 65 Bulletin C", "CEI/IEC 62209", "CALIPROBE"] [intro] =>This document contains calibration reports for a COMOSAR Dosimetric E-Field Probe and a COMOSAR Reference Dipole, both manufactured by MVG (Microwave Vision Group). The E-Field Probe calibration, performed on September 18, 2024, details the probe's sensitivity, linearity, and isotropy, ensuring accurate electric field measurements. The probe, model SSE2 with serial number SN 08/21 EPGO352, was calibrated using the CALIPROBE test bench and is intended for use with MVG COMOSAR systems.
The Reference Dipole calibration report, dated July 4, 2023, covers a 2450 MHz dipole with serial number SN 30/14 DIP2G450-335. This report outlines the return loss, impedance, and mechanical dimensions of the dipole, verifying its compliance with IEEE 1528, OET 65 Bulletin C, and CEI/IEC 62209 standards. Validation measurements in both head and body simulating liquids are included, demonstrating the dipole's performance within specified SAR limits. Both calibrations are traceable to international standards, ensuring the reliability of SAR testing results.
)
Array ( [0] => Array ( [id] => 8306445 [file_sha256] => [applicationId] => Dpxt/CTco7iVmqcBMv+D8g== [description] => MPE1 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4078247 [submissionDate] => 2025-05-20 00:00:00 [dateAvailable] => 2025-05-20 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2BOXK-MIHEALTH02 [cleanFccId] => 2BOXKMIHEALTH02 [exif] => 0 ) )