Conducted Spurious Emission Test Report for NR Band n7A

Appendix B.3 for NR Band n7A(2500-2570)_Part6-7_r1

This document presents the results of conducted spurious emission testing performed on a device operating in NR Band n7A. The tests were conducted at the ADR Test and Certification Center, and the report is identified by the number TR-25ADRTCC7007. The primary objective of these tests is to assess the device's compliance with regulatory limits for spurious emissions, ensuring that its operation does not cause undue interference to other radio services.

The testing methodology involves measuring the power levels of spurious emissions across a wide frequency range, from 9 kHz to 25.7 GHz, under various operating conditions. These conditions include different modulation schemes (DFT-Pi2BPSK and DFT-QPSK) and resource block configurations (Edge_1RB_Left). The tests are performed at low, middle, and high channel frequencies (LCH, MCH, HCH) to comprehensively evaluate the device's emission characteristics across its entire operating band. The results are presented in the form of spectrum plots and tables, showing the measured power levels and their compliance with the specified limits. The report includes detailed information on the test setup, equipment used, and procedures followed to ensure the accuracy and reliability of the measurements.


File Info : application/pdf, 5 Pages, 5.74MB

Download
Acrobat Distiller 11.0 (Windows)
ADR: NR Band n7A, TR-25ADRTCC7007, DFT-Pi2BPSK, DFT-QPSK, Edge_1RB_Left, 15KHz, 5MHz, 10MHz, 15MHz, 20MHz, 25MHz