This document presents a comprehensive test report detailing the Spurious RF Conducted Emissions analysis. The report outlines the test setup, which includes the EUT (Equipment Under Test) connected to a spectrum analyzer. It specifies the applicable limits according to FCC regulations, ensuring that emissions outside the designated frequency bands are appropriately attenuated.
The test procedure involves calibrating the measuring instrument, positioning the EUT, and connecting it to the measurement instrument via a low-loss cable. The spectrum analyzer's RBW is set to 1 MHz, and the highest amplitude on the spectral display is measured and recorded. The report includes detailed test results, noting that measurements are taken from 9KHz to the 10th harmonic of the fundamental frequency. The lowest, middle, and highest channels are tested to verify spurious emissions and band edge performance. The report also states that emissions attenuated by more than 20dB below the permissible value are not reported.
Array ( [0] => Array ( [url_sha] => ccb26e621fcc3eb8f928d66842cb5ef4096e4fdcf5f1d4880df31e24e11c0fda [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8099638 [href_text] => Test Report 5G WIFI 3 [href_description] => Shenzhen Qichang Intelligent Technology Co., Ltd DT3 Smart Tablet 2BAK2-DT3 2BAK2DT3 dt3 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8099638 [http_size] => 5062229 [file_sha256] => b62913e57a7973c70daadbd8a3cd3f594ecc36440d433df1109890e20d1673b0 [domain] => document.fccid ) ) Array ( [file_sha256] => b62913e57a7973c70daadbd8a3cd3f594ecc36440d433df1109890e20d1673b0 [cleanFccId] => 2BAK2DT3 [title] => BCTC Test Report: Spurious RF Conducted Emissions Analysis [description] => Detailed analysis of Spurious RF Conducted Emissions, covering test setups, limits, procedures, and results for 5G WIFI 3. [brand_name] => BCTC [keywords] => [] [intro] =>This document presents a comprehensive test report detailing the Spurious RF Conducted Emissions analysis. The report outlines the test setup, which includes the EUT (Equipment Under Test) connected to a spectrum analyzer. It specifies the applicable limits according to FCC regulations, ensuring that emissions outside the designated frequency bands are appropriately attenuated.
The test procedure involves calibrating the measuring instrument, positioning the EUT, and connecting it to the measurement instrument via a low-loss cable. The spectrum analyzer's RBW is set to 1 MHz, and the highest amplitude on the spectral display is measured and recorded. The report includes detailed test results, noting that measurements are taken from 9KHz to the 10th harmonic of the fundamental frequency. The lowest, middle, and highest channels are tested to verify spurious emissions and band edge performance. The report also states that emissions attenuated by more than 20dB below the permissible value are not reported.
)
Array ( [0] => Array ( [id] => 8099638 [file_sha256] => [applicationId] => vMXx14LhNfxhiVwTT9mBfw== [description] => Test Report 5G WIFI 3 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => Test Report [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 5062231 [submissionDate] => 2025-03-06 00:00:00 [dateAvailable] => 2025-03-06 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2BAK2-DT3 [cleanFccId] => 2BAK2DT3 [exif] => 0 ) )