Occupied Bandwidth Test Results for P24a0005 Device

Test report part 4

This document presents the occupied bandwidth test results for the P24a0005 device, as part of a comprehensive compliance testing process. The tests were conducted across three different modulation schemes: C4FM, Narrowband (NB), and Time Division Multiple Access (TDMA), at three distinct frequencies: 138.035 MHz, 150.075 MHz, and 173.965 MHz. The results are presented in the form of spectrum analyzer plots, showing the occupied bandwidth for each configuration.

Each test setup includes key parameters such as center frequency, span, resolution bandwidth, video bandwidth, and total power. The occupied bandwidth is measured, along with the transmit frequency error and x dB bandwidth. The percentage of occupied bandwidth power and x dB values are also recorded. The data provides a detailed analysis of the device's spectral characteristics under different operating conditions, ensuring compliance with regulatory requirements.

The tests were performed using a Keysight Spectrum Analyzer, and the results are presented in a clear and concise manner. This document serves as an annex to the main test report, providing supporting data for the overall compliance assessment of the P24a0005 device.


File Info : application/pdf, 0 Pages, 472.53KB

Download

Compliance Testing: P24a0005, C4FM, NB, TDMA, 138.035 MHz, 150.075 MHz, 173.965 MHz