This document presents the appendix test data for an Anbotek product safety assessment. The report, identified by number 1812C50045712501, includes a series of tests conducted between February 14, 2025, and February 25, 2025. The tests were performed by Test Engineer Qiangfei Yang and audited by Justin Feng, under controlled conditions of 20.2°C temperature and 46.8% relative humidity at a pressure of 101kPa.
The appendix contains detailed results for -6dB bandwidth, 99% occupied bandwidth, duty cycle, peak output power, power spectral density, bandedge compliance, and spurious emissions. Each test condition is meticulously documented, including antenna configuration, data rate, frequency, and corresponding limits. The data is presented in both tabular and graphical formats, providing a comprehensive overview of the product's performance against specified safety standards. All tests passed the required limits.
The tests were conducted by Shenzhen Anbotek Compliance Laboratory Limited, ensuring adherence to rigorous testing protocols and quality standards. This report provides essential data for evaluating the safety and compliance of the tested product.