FCC SAR Evaluation Report for Tracki 4G (TRKM010-C)

SAR Test report 1

This report details the Specific Absorption Rate (SAR) evaluation for the Tracki 4G device, model number TRKM010-C, manufactured by Trackimo INC. The evaluation was conducted by Guangdong Asia Hongke Test Technology Limited, adhering to the requirements outlined in FCC 47 CFR Part 2(2.1093) and IEEE Std 1528-2013. The report assesses the device's compliance with localized SAR limits for general population/uncontrolled exposure.

The testing methodology involved using the SATIMO OPENSAR system, employing a high-precision robot and dosimetric probes calibrated for accurate measurements in simulated tissue. The device was tested in various configurations to determine the maximum SAR values across different frequency bands, including LTE and WLAN. The report includes detailed descriptions of the measurement system, procedures, and results, ensuring transparency and reliability in the assessment of the device's RF exposure characteristics.

The maximum reported SAR value for the Tracki 4G device is 1.137 W/kg, which is below the FCC limit of 1.6 W/kg. This confirms that the device complies with the specified SAR limits for general population/uncontrolled exposure.


File Info : application/pdf, 85 Pages, 5.02MB

Download
Aspose.Words for .NET 15.1.0.0
tags: ["Tracki 4G", "TRKM010-C", "2AAI6-TRKM010-C", "FCC 47 CFR Part 2(2.1093)", "IEEE Std 1528-2013", "SAR", "AITSZ24061413FW4"]
Array
(
    [0] => Array
        (
            [url_sha] => 386f348542fa2e416092279832de9d6a342d80e3aab7af24f01644b43a418534
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8086780
            [href_text] => SAR Test Report 1
            [href_description] => Trackimo INC. TRKM010-C Tracki 4G 2AAI6-TRKM010-C 2AAI6TRKM010C trkm010 c
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8086780
            [http_size] => 5267789
            [file_sha256] => a8e715a3e5f67d854d1b0c61202647c6762dcbe6bea8c69e0a2d0e71c9973186
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => 246e62324e3e8bcb12db05233816aecf13f74d9f99ac9ca00d5f9dfed7c7962f
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8086520
            [href_text] => SAR Test report 1
            [href_description] => Trackimo INC. TRKM010-C Tracki 4G 2AAI6-TRKM010-C 2AAI6TRKM010C trkm010 c
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8086520
            [http_size] => 5267789
            [file_sha256] => a8e715a3e5f67d854d1b0c61202647c6762dcbe6bea8c69e0a2d0e71c9973186
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => a8e715a3e5f67d854d1b0c61202647c6762dcbe6bea8c69e0a2d0e71c9973186
    [cleanFccId] => 2AAI6TRKM010C
    [title] => FCC SAR Evaluation Report for Tracki 4G (TRKM010-C)
    [description] => SAR evaluation report in accordance with FCC 47 CFR Part 2(2.1093) and IEEE Std 1528-2013 for the Tracki 4G device. Testing was performed by Guangdong Asia Hongke.
    [brand_name] => Trackimo, Tracki
    [keywords] => ["Tracki 4G", "TRKM010-C", "2AAI6-TRKM010-C", "FCC 47 CFR Part 2(2.1093)", "IEEE Std 1528-2013", "SAR", "AITSZ24061413FW4"]
    [intro] => 

This report details the Specific Absorption Rate (SAR) evaluation for the Tracki 4G device, model number TRKM010-C, manufactured by Trackimo INC. The evaluation was conducted by Guangdong Asia Hongke Test Technology Limited, adhering to the requirements outlined in FCC 47 CFR Part 2(2.1093) and IEEE Std 1528-2013. The report assesses the device's compliance with localized SAR limits for general population/uncontrolled exposure.

The testing methodology involved using the SATIMO OPENSAR system, employing a high-precision robot and dosimetric probes calibrated for accurate measurements in simulated tissue. The device was tested in various configurations to determine the maximum SAR values across different frequency bands, including LTE and WLAN. The report includes detailed descriptions of the measurement system, procedures, and results, ensuring transparency and reliability in the assessment of the device's RF exposure characteristics.

The maximum reported SAR value for the Tracki 4G device is 1.137 W/kg, which is below the FCC limit of 1.6 W/kg. This confirms that the device complies with the specified SAR limits for general population/uncontrolled exposure.

)
Array
(
    [0] => Array
        (
            [id] => 8086520
            [file_sha256] => 
            [applicationId] => DH2mWVSe5hzP1nWLgDqvtQ==
            [description] => SAR Test report 1
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 5267791
            [submissionDate] => 2025-03-03 00:00:00
            [dateAvailable] => 2025-03-03 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2AAI6-TRKM010-C
            [cleanFccId] => 2AAI6TRKM010C
            [exif] => 0
        )

)