This document presents the appendix test data for an Anbotek product safety report. The report, identified by number 1812C50045312501, includes a comprehensive analysis of various performance metrics. The tests were conducted between February 14, 2025, and February 25, 2025, by Test Engineer Qiangfei Yang and audited by Justin Feng. The testing environment was maintained at a temperature of 20.2°C and a relative humidity of 46.8%, with a pressure of 101kPa.
The appendix focuses on key parameters such as -6dB bandwidth, 99% occupied bandwidth, duty cycle, peak output power, power spectral density, bandedge compliance, and spurious emissions. Detailed measurements and spectrum analyzer plots are provided for each test, covering different frequency channels (2405 MHz, 2430 MHz, and 2460 MHz) and antenna configurations (ANT1). The results indicate that the device meets the specified limits for each test, ensuring its compliance with relevant safety and performance standards. The data presented in this appendix serves as supporting evidence for the overall product safety assessment.