This document presents the RF test report for the Quectel BG770A-GL LTE Module. The module was tested to ensure compliance with the requirements outlined in FCC CFR47 Part 2 (2021) and FCC CFR47 Part 27C (2021). The tests were conducted by TA Technology (Shanghai) Co., Ltd., and the results demonstrate that the equipment is capable of meeting the documented requirements.
The report includes details on various tests performed, including RF Power Output, Effective Isotropic Radiated Power, Occupied Bandwidth, Band Edge Compliance, Peak-to-Average Power Ratio (PAPR), Frequency Stability, Spurious Emissions at Antenna Terminals, and Radiated Spurious Emission. The test setup, methods of measurement, and applicable limits are described for each test. The report also includes a list of the main test instruments used during the testing process.
The BG770A-GL supports from Cat NB1 (3GPP R13) to Cat NB2 (3GPP R14) only by FW updating, the hardware remains the same. The detailed product change description please refers to the Difference Declaration Letter.