This document presents the exposure test report for the Sepura SCG2221 TETRA mobile radio, conducted by TÜV SÜD. The report confirms compliance with FCC CFR 47 Part 1.1310: 2021 regarding radiofrequency radiation exposure limits. The tested sample, identified by serial number 1PR002230GP58OM, met the requirements at a minimum distance of 40 cm with time averaging of 6 minutes.
The report details the test setup, methodology, and results, including measurements of electric and magnetic fields. It also addresses multiple frequency summation and provides environmental conditions during testing. The SCG2221 supports TETRA, Bluetooth, and 2.4GHz WLAN, with simultaneous transmission capabilities. The report includes information on manufacturer-declared variants, such as the Basic, Standard, and Premium models, each with unique features and identification numbers for North America.
The tests were performed at TÜV SÜD's Fareham Test Laboratory, and the report includes a list of test equipment used and their calibration details. The document is marked as COMMERCIAL-IN-CONFIDENCE and is intended for Sepura Limited and TÜV SÜD's internal use.