This document presents an RF exposure evaluation conducted by Anbotek for a device with FCC ID 2ANBQ-BR16. The evaluation adheres to KDB 447498 D01 guidelines for mobile and portable devices, as well as FCC 1.1310 regulations concerning human exposure to radio frequency radiation.

The report details the assessment process, which involves comparing calculated values against established SAR test exclusion thresholds. These thresholds are determined based on factors such as the device's maximum power output, operating frequency, and minimum separation distance. The evaluation specifically considers the 1-g and 10-g SAR test exclusion thresholds for frequencies between 100 MHz and 6 GHz.

The results of the evaluation indicate that the device meets the SAR test exclusion criteria, meaning that a standalone SAR test is not required. This conclusion is based on the calculations and comparisons presented in the report, which demonstrate that the device's RF exposure levels are below the established limits.


File Info : application/pdf, 1 Pages, 346.25KB

Download
WPS 文字
tags: ["RF Exposure Evaluation", "2ANBQ-BR16", "FCC 1.1310", "KDB 447498 D01", "Mobile Devices", "Portable Devices", "RF Exposure Procedures", "Equipment Authorization Policies v06"]
Array
(
    [0] => Array
        (
            [url_sha] => 3c40f2caf9c65bbea0ad08d4711598a04ddde360326e3db636dd3092760f523c
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8263186
            [href_text] => RF Exposure
            [href_description] => Momax Technology (Shenzhen) Limited BR16  2ANBQ-BR16 2ANBQBR16 br16
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8263186
            [http_size] => 354555
            [file_sha256] => 990726af952d9526a40f37c903e0e47f8bb91b65eee4c43b53f62e033f267366
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 990726af952d9526a40f37c903e0e47f8bb91b65eee4c43b53f62e033f267366
    [cleanFccId] => 2ANBQBR16
    [title] => Anbotek RF Exposure Evaluation for 2ANBQ-BR16 Device
    [description] => RF exposure evaluation report by Anbotek for FCC ID 2ANBQ-BR16, assessing compliance with safety standards and regulations for portable devices.
    [brand_name] => Anbotek
    [keywords] => ["RF Exposure Evaluation", "2ANBQ-BR16", "FCC 1.1310", "KDB 447498 D01", "Mobile Devices", "Portable Devices", "RF Exposure Procedures", "Equipment Authorization Policies v06"]
    [intro] => 

This document presents an RF exposure evaluation conducted by Anbotek for a device with FCC ID 2ANBQ-BR16. The evaluation adheres to KDB 447498 D01 guidelines for mobile and portable devices, as well as FCC 1.1310 regulations concerning human exposure to radio frequency radiation.

The report details the assessment process, which involves comparing calculated values against established SAR test exclusion thresholds. These thresholds are determined based on factors such as the device's maximum power output, operating frequency, and minimum separation distance. The evaluation specifically considers the 1-g and 10-g SAR test exclusion thresholds for frequencies between 100 MHz and 6 GHz.

The results of the evaluation indicate that the device meets the SAR test exclusion criteria, meaning that a standalone SAR test is not required. This conclusion is based on the calculations and comparisons presented in the report, which demonstrate that the device's RF exposure levels are below the established limits.

)
Array
(
    [0] => Array
        (
            [id] => 8263186
            [file_sha256] => 
            [applicationId] => Hhdy9MaXU60wwPganJHySA==
            [description] => RF Exposure
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 354556
            [submissionDate] => 2025-05-06 00:00:00
            [dateAvailable] => 2025-05-06 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2ANBQ-BR16
            [cleanFccId] => 2ANBQBR16
            [exif] => 0
        )

)