RF Exposure Evaluation for Ceiling Fan Light Remote Control

AiTSZ-250313017FW2_FCC RF EXPOSURE

This report details the Radio Frequency (RF) exposure evaluation conducted on a ceiling fan light remote control manufactured by Zhongshan Kedu Lighting Co., Ltd. The evaluation was performed by Guangdong Asia Hongke Test Technology Limited to ensure compliance with Federal Communications Commission (FCC) regulations, specifically 47 CFR §1.1310 and §2.1093, and following the guidelines outlined in KDB447498 D01 General RF Exposure Guidance v06.

The tested device, identified by FCC ID 2BLKG-RXFL-KD002 and model number RXFL8001 (with series models RXFL8002 through RXFL8009), operates at a frequency of 433.92MHz using ASK modulation. The evaluation considered the device's antenna type (PCB antenna) and gain (0dBi) to determine if standalone SAR testing was required. The results indicate that the device meets the SAR test exclusion thresholds, ensuring that the public is not exposed to excessive radio frequency energy levels. The report includes details on the test facility, environmental conditions during testing, measurement uncertainty, and the methodology used for evaluation.


File Info : application/pdf, 7 Pages, 321.86KB

Download
Microsoft Word 2016 Microsoft Word 2016
tags: ["RXFL8001", "RXFL8002", "RXFL8003", "RXFL8004", "RXFL8005", "RXFL8006", "RXFL8007", "RXFL8008", "RXFL8009", "2BLKG-RXFL-KD002", "AiTSZ-250313017FW2"]
Array
(
    [0] => Array
        (
            [url_sha] => ff4a5285e2ba1180d4a807751c7eaa4b27f547d2b7c18b3bca47be8c270442eb
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8266854
            [href_text] => AiTSZ-250313017FW2_FCC RF EXPOSURE
            [href_description] => Zhongshan Kedu Lighting Co., Ltd RXFL-KD002 Ceiling fan light remote control 2BLKG-RXFL-KD002 2BLKGRXFLKD002 rxfl kd002
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8266854
            [http_size] => 329582
            [file_sha256] => 985d7c9c780479608008c70a6fe2e72f2df830c6942876590bb1c819da75d3ca
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 985d7c9c780479608008c70a6fe2e72f2df830c6942876590bb1c819da75d3ca
    [cleanFccId] => 2BLKGRXFLKD002
    [title] => RF Exposure Evaluation for Ceiling Fan Light Remote Control
    [description] => This report evaluates the RF exposure of a ceiling fan light remote control, ensuring compliance with FCC guidelines and SAR exclusion thresholds.
    [brand_name] => N/A
    [keywords] => ["RXFL8001", "RXFL8002", "RXFL8003", "RXFL8004", "RXFL8005", "RXFL8006", "RXFL8007", "RXFL8008", "RXFL8009", "2BLKG-RXFL-KD002", "AiTSZ-250313017FW2"]
    [intro] => 

This report details the Radio Frequency (RF) exposure evaluation conducted on a ceiling fan light remote control manufactured by Zhongshan Kedu Lighting Co., Ltd. The evaluation was performed by Guangdong Asia Hongke Test Technology Limited to ensure compliance with Federal Communications Commission (FCC) regulations, specifically 47 CFR §1.1310 and §2.1093, and following the guidelines outlined in KDB447498 D01 General RF Exposure Guidance v06.

The tested device, identified by FCC ID 2BLKG-RXFL-KD002 and model number RXFL8001 (with series models RXFL8002 through RXFL8009), operates at a frequency of 433.92MHz using ASK modulation. The evaluation considered the device's antenna type (PCB antenna) and gain (0dBi) to determine if standalone SAR testing was required. The results indicate that the device meets the SAR test exclusion thresholds, ensuring that the public is not exposed to excessive radio frequency energy levels. The report includes details on the test facility, environmental conditions during testing, measurement uncertainty, and the methodology used for evaluation.

)
Array
(
    [0] => Array
        (
            [id] => 8266854
            [file_sha256] => 
            [applicationId] => JAxiRrjDKefOf0JgjUcgfA==
            [description] => AiTSZ-250313017FW2_FCC RF EXPOSURE
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 329582
            [submissionDate] => 2025-05-07 00:00:00
            [dateAvailable] => 2025-05-07 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2BLKG-RXFL-KD002
            [cleanFccId] => 2BLKGRXFLKD002
            [exif] => 0
        )

)