RF Exposure Test Report for 2A8ZB-G302 Portable Device

RF exposure

This document details the RF exposure evaluation for the 2A8ZB-G302 portable device, conducted by Shenzhen CTB Testing Co., Ltd. The evaluation ensures compliance with FCC regulations, specifically §15.247(e)(i) and §1.1307(b)(1), which mandate that devices operate in a manner that does not expose the public to excessive radio frequency energy levels. The assessment follows the guidelines outlined in KDB447498 D01 General RF Exposure Guidance V06.

The report focuses on SAR (Specific Absorption Rate) test exclusion thresholds for frequencies between 100 MHz and 6 GHz, with test separation distances of ≤ 50 mm. The SAR exclusion is determined by a formula involving the maximum channel power (including tune-up tolerance), minimum test separation distance, and the RF channel transmit frequency. The results are compared against established limits for 1-g SAR and 10-g extremity SAR.

The document presents detailed tables for EDR, BLE:1M, and BLE:2M modes, including channel frequency, conducted power, tune-up power, distance, calculated results, and SAR test exclusion status. The conclusion states that the maximum calculated result is below the FCC limit for 1g SAR, indicating compliance.


File Info : application/pdf, 1 Pages, 75.16KB

Download
Microsoft Word 2016 Microsoft Word 2016
tags: ["2A8ZB-G302", "G302", "KDB447498 D01", "SAR exclusion", "RF exposure"]
Array
(
    [0] => Array
        (
            [url_sha] => 8a1f28311f71138718207726c03516f7536e5660f6d49812f260e7256d6cece6
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8058166
            [href_text] => RF exposure
            [href_description] => Shenzhen Weiwo Intelligent Electronics Co., Ltd G302 Smart Watch 2A8ZB-G302 2A8ZBG302 g302
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8058166
            [http_size] => 76960
            [file_sha256] => 8d13a5b40ce54b6289be044dea080d6fc4947a70f715857b37aec31926ea3dcd
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => cde22f2fe7d56ab7f4b5a501575c9386390c90112099637247731c36c037c485
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8058145
            [href_text] => RF exposure
            [href_description] => Shenzhen Weiwo Intelligent Electronics Co., Ltd G302 Smart Watch 2A8ZB-G302 2A8ZBG302 g302
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8058145
            [http_size] => 76960
            [file_sha256] => 8d13a5b40ce54b6289be044dea080d6fc4947a70f715857b37aec31926ea3dcd
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 8d13a5b40ce54b6289be044dea080d6fc4947a70f715857b37aec31926ea3dcd
    [cleanFccId] => 2A8ZBG302
    [title] => RF Exposure Test Report for 2A8ZB-G302 Portable Device
    [description] => RF exposure test report for the 2A8ZB-G302 portable device, ensuring compliance with FCC guidelines and KDB447498 D01 for SAR exclusion.
    [brand_name] => Shenzhen CTB Testing Co., Ltd.
    [keywords] => ["2A8ZB-G302", "G302", "KDB447498 D01", "SAR exclusion", "RF exposure"]
    [intro] => 

This document details the RF exposure evaluation for the 2A8ZB-G302 portable device, conducted by Shenzhen CTB Testing Co., Ltd. The evaluation ensures compliance with FCC regulations, specifically §15.247(e)(i) and §1.1307(b)(1), which mandate that devices operate in a manner that does not expose the public to excessive radio frequency energy levels. The assessment follows the guidelines outlined in KDB447498 D01 General RF Exposure Guidance V06.

The report focuses on SAR (Specific Absorption Rate) test exclusion thresholds for frequencies between 100 MHz and 6 GHz, with test separation distances of ≤ 50 mm. The SAR exclusion is determined by a formula involving the maximum channel power (including tune-up tolerance), minimum test separation distance, and the RF channel transmit frequency. The results are compared against established limits for 1-g SAR and 10-g extremity SAR.

The document presents detailed tables for EDR, BLE:1M, and BLE:2M modes, including channel frequency, conducted power, tune-up power, distance, calculated results, and SAR test exclusion status. The conclusion states that the maximum calculated result is below the FCC limit for 1g SAR, indicating compliance.

)
Array
(
    [0] => Array
        (
            [id] => 8058145
            [file_sha256] => 
            [applicationId] => SAIIWbs+k6zOIrVXXEA9Dg==
            [description] => RF exposure
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 76960
            [submissionDate] => 2025-02-19 00:00:00
            [dateAvailable] => 2025-02-19 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2A8ZB-G302
            [cleanFccId] => 2A8ZBG302
            [exif] => 0
        )

)