This document presents the Radio Frequency (RF) exposure evaluation for a device with FCC ID 2BA8X-JR-OE3. The evaluation is conducted in accordance with KDB 447498 D01 V06 and part 2.1093 of the FCC guidelines. The primary objective is to determine if the device meets the Specific Absorption Rate (SAR) test exclusion thresholds, ensuring it complies with safety standards for general population exposure conditions.
The evaluation considers standalone 1-g head or body and 10-g extremity SAR. The document outlines the formula used to calculate the exclusion thresholds for devices operating between 100 MHz and 6 GHz with test separation distances of 50 mm or less. The formula incorporates the maximum power of the channel, the minimum test separation distance, and the RF channel transmit frequency. The results of the calculations are presented, demonstrating that the device satisfies the SAR test exclusion thresholds. Therefore, a SAR test is not required.
File Info : application/pdf, 1 Pages, 138.53KB