This document presents the Radio Frequency (RF) exposure evaluation for the Hangzhou Huiji Technology Co., Ltd Treadmill, model CT07R, in accordance with Federal Communications Commission (FCC) guidelines. The evaluation assesses the potential RF exposure from Bluetooth and Wi-Fi (2.4G Band) transmissions, ensuring compliance with safety limits for general population/uncontrolled environments.
The report details the conducted power results for Bluetooth Low Energy (BLE) and Wi-Fi modes, including frequency ranges, channel numbers, and modulation types. Manufacturing tolerances are considered to ensure accurate assessment of RF output power. Standalone evaluation results demonstrate that the device meets the SAR test exclusion thresholds, indicating that further SAR testing is not required.
The evaluation confirms that the treadmill complies with FCC limits for RF exposure, as per 47 CFR 2.1093, and meets the SAR Exclusion Threshold per KDB 447498 v06. The report also includes a description of the test facility, including NVLAP accreditation code, FCC designation number, CAB identifier, and CNAS registration number.
Array ( [0] => Array ( [url_sha] => 514881caafc293b467209e0e1a003cdfdb92b5fad4b2223cf08e531328e3812e [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8087390 [href_text] => RF Exposure Evaluation_FCC [href_description] => Hangzhou Huiji Technology Co., Ltd CT07R Treadmill 2BNLB-CT07R 2BNLBCT07R ct07r [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8087390 [http_size] => 318888 [file_sha256] => 8a0ecf47438b70734c352533a1ea1a0b8ff91f5444a92f087003ecbd0d48bfc8 [domain] => document.fccid ) ) Array ( [file_sha256] => 8a0ecf47438b70734c352533a1ea1a0b8ff91f5444a92f087003ecbd0d48bfc8 [cleanFccId] => 2BNLBCT07R [title] => FCC RF Exposure Evaluation for Hangzhou Huiji Treadmill [description] => This report details the RF exposure evaluation for the Hangzhou Huiji Technology Co., Ltd Treadmill, model CT07R, ensuring compliance with FCC standards. [brand_name] => Hangzhou Huiji Technology Co., Ltd [keywords] => ["2BNLB-CT07R", "CT07R", "Treadmill", "1257A1-V1", "1257A1-X1-V1", "CN5024", "CN0071", "L4595", "254912", "600167-0"] [intro] =>This document presents the Radio Frequency (RF) exposure evaluation for the Hangzhou Huiji Technology Co., Ltd Treadmill, model CT07R, in accordance with Federal Communications Commission (FCC) guidelines. The evaluation assesses the potential RF exposure from Bluetooth and Wi-Fi (2.4G Band) transmissions, ensuring compliance with safety limits for general population/uncontrolled environments.
The report details the conducted power results for Bluetooth Low Energy (BLE) and Wi-Fi modes, including frequency ranges, channel numbers, and modulation types. Manufacturing tolerances are considered to ensure accurate assessment of RF output power. Standalone evaluation results demonstrate that the device meets the SAR test exclusion thresholds, indicating that further SAR testing is not required.
The evaluation confirms that the treadmill complies with FCC limits for RF exposure, as per 47 CFR 2.1093, and meets the SAR Exclusion Threshold per KDB 447498 v06. The report also includes a description of the test facility, including NVLAP accreditation code, FCC designation number, CAB identifier, and CNAS registration number.
)
Array ( [0] => Array ( [id] => 8087390 [file_sha256] => [applicationId] => 9h7208JVrN4Qr6tmdgDAGA== [description] => RF Exposure Evaluation_FCC [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 318889 [submissionDate] => 2025-03-03 00:00:00 [dateAvailable] => 2025-03-03 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2BNLB-CT07R [cleanFccId] => 2BNLBCT07R [exif] => 0 ) )