This document presents the calibration certificate for the EX3DV4 probe, serial number 7693, performed by Schmid & Partner Engineering AG on November 20, 2024. The calibration adheres to rigorous standards and procedures, ensuring traceability to national standards. The certificate details various calibration parameters, including sensor characteristics, modulation response, and tissue simulating media performance.
The calibration process involves assessing the probe's sensitivity in free space and within tissue simulating liquids, accounting for frequency response and diode compression. Numerical linearization parameters are determined to enhance accuracy across different modulation signals. The document also includes assessments of spherical isotropy and dynamic range, providing a comprehensive evaluation of the probe's performance.
This certificate serves as a crucial reference for ensuring the accuracy and reliability of measurements obtained using the EX3DV4 probe in various applications. The information contained herein is essential for interpreting measurement data and maintaining the integrity of research and development activities.
Array ( [0] => Array ( [url_sha] => 4730c92b1107fe7c5716f0433df448658ba8d495dfe90bc57ab5e0b4b4a1ba64 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8095020 [href_text] => SAR test report appendix C-2 [href_description] => The Light Phone Inc. GOLIGHT3 Light Phone III 2AIBC-GOLIGHT3 2AIBCGOLIGHT3 golight3 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8095020 [http_size] => 5040763 [file_sha256] => 83e6a0c5d483aaea35ee1d61a22fcd29c7fba91a254af898adee7483b40a4c9d [domain] => document.fccid ) [1] => Array ( [url_sha] => de8031cfa474f870f34385fcfc47b13eb2ee7ed8a5ead71811d7c839152c5946 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8094689 [href_text] => Appendix C Calibration certificate 2 [href_description] => The Light Phone Inc. GOLIGHT3 2AIBC-GOLIGHT3 2AIBCGOLIGHT3 golight3 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8094689 [http_size] => 5040763 [file_sha256] => 83e6a0c5d483aaea35ee1d61a22fcd29c7fba91a254af898adee7483b40a4c9d [domain] => document.fccid ) [2] => Array ( [url_sha] => 4551cc6a4346fef678c63bf7003f42469eac8111132d99fab8134677f05bee10 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8094952 [href_text] => Appendix C Calibration Certificate R00 2 [href_description] => The Light Phone Inc. GOLIGHT3 Light Phone III 2AIBC-GOLIGHT3 2AIBCGOLIGHT3 golight3 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8094952 [http_size] => 5040763 [file_sha256] => 83e6a0c5d483aaea35ee1d61a22fcd29c7fba91a254af898adee7483b40a4c9d [domain] => document.fccid ) ) Array ( [file_sha256] => 83e6a0c5d483aaea35ee1d61a22fcd29c7fba91a254af898adee7483b40a4c9d [cleanFccId] => 2AIBCGOLIGHT3 [title] => EX3DV4 Calibration Certificate: SN:7693, November 20, 2024 [description] => Calibration certificate for EX3DV4 probe SN:7693, issued November 20, 2024. Includes calibration parameters, modulation calibration, and more. [brand_name] => Schmid & Partner Engineering AG [keywords] => ["EX3DV4", "SN:7693", "EX-7693_Nov24", "QA CAL-01.v10", "QA CAL-12.v10", "QA CAL-14.v7", "QA CAL-23.v6", "QA CAL-25.v8"] [intro] =>This document presents the calibration certificate for the EX3DV4 probe, serial number 7693, performed by Schmid & Partner Engineering AG on November 20, 2024. The calibration adheres to rigorous standards and procedures, ensuring traceability to national standards. The certificate details various calibration parameters, including sensor characteristics, modulation response, and tissue simulating media performance.
The calibration process involves assessing the probe's sensitivity in free space and within tissue simulating liquids, accounting for frequency response and diode compression. Numerical linearization parameters are determined to enhance accuracy across different modulation signals. The document also includes assessments of spherical isotropy and dynamic range, providing a comprehensive evaluation of the probe's performance.
This certificate serves as a crucial reference for ensuring the accuracy and reliability of measurements obtained using the EX3DV4 probe in various applications. The information contained herein is essential for interpreting measurement data and maintaining the integrity of research and development activities.
)
Array ( [0] => Array ( [id] => 8094689 [file_sha256] => [applicationId] => E0XYqQuJXxshPFaDgmTksQ== [description] => Appendix C Calibration certificate 2 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 5040765 [submissionDate] => 2025-03-05 00:00:00 [dateAvailable] => 2025-03-05 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 0 [source] => 0 [fccId] => 2AIBC-GOLIGHT3 [cleanFccId] => 2AIBCGOLIGHT3 [exif] => 0 ) )