This document presents an RF exposure evaluation conducted by Bay Area Compliance Laboratories Corp. (Dongguan). The evaluation adheres to §15.247(i), § 2.1093, and §1.1310 regulations, ensuring that the device operates in a manner that does not expose the public to excessive radio frequency energy levels, as per the Commission's guidelines.
The evaluation follows KDB447498 D01 General RF Exposure Guidance v06, utilizing the 1-g and 10-g SAR test exclusion thresholds for frequencies between 100 MHz and 6 GHz at test separation distances of ≤ 50 mm. The calculation considers the maximum power of the channel, including tune-up tolerance, and the minimum test separation distance.
The measurement result indicates that the maximum conducted power, including tune-up tolerance, is -3 dBm (0.5 mW). The calculated value, based on the formula provided, is 0.2, which is less than the threshold of 3.0. Therefore, the device is compliant, and a stand-alone SAR evaluation is deemed unnecessary.