E-UTRA Band 2 Test Data: Appendix D Part 6 Compliance

Appendix D Test Data for E-UTRA Band 2_Part6

This document presents comprehensive test data for E-UTRA Band 2, specifically Appendix D, Part 6. The data encompasses various modulation schemes, including QPSK and 16QAM, across different channel bandwidths (10MHz and 15MHz) and resource block configurations (1RB#0). The tests cover a wide frequency range, from 9 kHz to 20 GHz, to ensure compliance with regulatory limits.

The measurements include spurious emissions, conducted power, and frequency stability. The data is presented in the form of spectrum analyzer plots, showing the signal levels at different frequencies. The plots are annotated with marker values, indicating the peak signal levels and their corresponding frequencies. The test results demonstrate that the device meets the required specifications for E-UTRA Band 2 operation.

The tests were conducted by Shenzhen LCS Compliance Testing Laboratory Ltd., a certified testing facility. The test setup and procedures followed industry-standard practices. The results are presented in a clear and concise manner, making it easy to assess the device's compliance with regulatory requirements. This document serves as evidence of the device's suitability for use in E-UTRA Band 2 networks.


File Info : application/pdf, 15 Pages, 5.85MB

Download
WPS 文字
tags: ["E-UTRA Band 2", "FCC ID: 055680125", "LCSA01025169EG", "QPSK", "16QAM", "18900", "18675", "19150", "19125"]
Array
(
    [0] => Array
        (
            [url_sha] => efc3c98f9b472cb318d4e867ebeb4d0ae0d192633ed0bc373027695bf650a5a7
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8266075
            [href_text] => Appendix D Test Data for E-UTRA Band 2_Part6
            [href_description] => SWAGTEK 680125 smartphone O55680125 O55680125 680125
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8266075
            [http_size] => 6133288
            [file_sha256] => 7ce004a82d067c3c537688f4f012c6cab3a37e07f0cbf732f18cc03e0c8df30c
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 7ce004a82d067c3c537688f4f012c6cab3a37e07f0cbf732f18cc03e0c8df30c
    [cleanFccId] => O55680125
    [title] => E-UTRA Band 2 Test Data: Appendix D Part 6 Compliance
    [description] => Explore comprehensive test data for E-UTRA Band 2, Appendix D, Part 6. This document details compliance testing and results for certification.
    [brand_name] => LCS Compliance Testing Laboratory Ltd.
    [keywords] => ["E-UTRA Band 2", "FCC ID: 055680125", "LCSA01025169EG", "QPSK", "16QAM", "18900", "18675", "19150", "19125"]
    [intro] => 

This document presents comprehensive test data for E-UTRA Band 2, specifically Appendix D, Part 6. The data encompasses various modulation schemes, including QPSK and 16QAM, across different channel bandwidths (10MHz and 15MHz) and resource block configurations (1RB#0). The tests cover a wide frequency range, from 9 kHz to 20 GHz, to ensure compliance with regulatory limits.

The measurements include spurious emissions, conducted power, and frequency stability. The data is presented in the form of spectrum analyzer plots, showing the signal levels at different frequencies. The plots are annotated with marker values, indicating the peak signal levels and their corresponding frequencies. The test results demonstrate that the device meets the required specifications for E-UTRA Band 2 operation.

The tests were conducted by Shenzhen LCS Compliance Testing Laboratory Ltd., a certified testing facility. The test setup and procedures followed industry-standard practices. The results are presented in a clear and concise manner, making it easy to assess the device's compliance with regulatory requirements. This document serves as evidence of the device's suitability for use in E-UTRA Band 2 networks.

)
Array
(
    [0] => Array
        (
            [id] => 8266075
            [file_sha256] => 
            [applicationId] => EIbK61odoXi+4BRzZKM/ug==
            [description] => Appendix D Test Data for E-UTRA Band 2_Part6
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => Test Report
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 6133290
            [submissionDate] => 2025-05-07 00:00:00
            [dateAvailable] => 2025-05-07 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => O55680125
            [cleanFccId] => O55680125
            [exif] => 0
        )

)