KUMI Smart Watch BLE Test Report: EMC and Radiated Emissions

BLE TEST REPORT P2

This document presents the EMC test report for the KUMI Smart Watch, model KUMI M2. The report details the testing procedures and results for compliance with 47 CFR Part 15, Subpart C 15.247(d) and ANSI C63.10-2013 standards. The tests cover power spectrum density, conducted band edges measurement, conducted spurious emissions, and radiated emissions, including those falling within restricted bands.

The report includes detailed test setups, limits, and data for each test performed. The EUT (Equipment Under Test) was tested in various modes, including TX (Transmitting) mode, and the results are presented in both horizontal and vertical polarities. The radiated emissions were measured across a wide frequency range, and the report includes plots and tables showing the measured levels and margins against the specified limits.

The test setup involved using RF test systems, spectrum analyzers, signal generators, and other calibrated equipment. The EUT was positioned on a rotating table in an anechoic chamber, and the antenna height and polarization were adjusted to maximize the measured signal strength. The report concludes that the KUMI Smart Watch complies with the applicable regulatory requirements.


File Info : application/pdf, 20 Pages, 1.53MB

Download

tags: ["KUMI Smart Watch", "KUMI M2", "BLE-TX", "BLE-TX-2402", "BLE-TX-2442", "BLA-EMC-202501-A8302", "47 CFR Part 15", "Subpart C 15.247(d)", "ANSI C63.10-2013"]
Array
(
    [0] => Array
        (
            [url_sha] => acfc6293079a3f84b85dd27e4d1bac05bf7d04f8d05fd8ff31dadb1882943b58
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8087430
            [href_text] => BLE TEST REPORT P2
            [href_description] => Kumi Technology Co., Ltd. KUMIM2 KUMI Smart Watch 2A2L4-KUMIM2 2A2L4KUMIM2 kumim2
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8087430
            [http_size] => 1605004
            [file_sha256] => 7bad5b4b4496724c3be00690a631e63cbebad8e55c6adb50e04b9b9b8bc919bc
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 7bad5b4b4496724c3be00690a631e63cbebad8e55c6adb50e04b9b9b8bc919bc
    [cleanFccId] => 2A2L4KUMIM2
    [title] => KUMI Smart Watch BLE Test Report: EMC and Radiated Emissions
    [description] => Comprehensive EMC test report for the KUMI Smart Watch, covering radiated emissions, power spectrum density, and band edge measurements.
    [brand_name] => Blue Asia
    [keywords] => ["KUMI Smart Watch", "KUMI M2", "BLE-TX", "BLE-TX-2402", "BLE-TX-2442", "BLA-EMC-202501-A8302", "47 CFR Part 15", "Subpart C 15.247(d)", "ANSI C63.10-2013"]
    [intro] => 

This document presents the EMC test report for the KUMI Smart Watch, model KUMI M2. The report details the testing procedures and results for compliance with 47 CFR Part 15, Subpart C 15.247(d) and ANSI C63.10-2013 standards. The tests cover power spectrum density, conducted band edges measurement, conducted spurious emissions, and radiated emissions, including those falling within restricted bands.

The report includes detailed test setups, limits, and data for each test performed. The EUT (Equipment Under Test) was tested in various modes, including TX (Transmitting) mode, and the results are presented in both horizontal and vertical polarities. The radiated emissions were measured across a wide frequency range, and the report includes plots and tables showing the measured levels and margins against the specified limits.

The test setup involved using RF test systems, spectrum analyzers, signal generators, and other calibrated equipment. The EUT was positioned on a rotating table in an anechoic chamber, and the antenna height and polarization were adjusted to maximize the measured signal strength. The report concludes that the KUMI Smart Watch complies with the applicable regulatory requirements.

)
Array
(
    [0] => Array
        (
            [id] => 8087430
            [file_sha256] => 
            [applicationId] => GdFXBO4X2QgaMcrV0qyFsg==
            [description] => BLE TEST REPORT P2
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => Test Report
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 1605006
            [submissionDate] => 2025-03-03 00:00:00
            [dateAvailable] => 2025-03-03 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2A2L4-KUMIM2
            [cleanFccId] => 2A2L4KUMIM2
            [exif] => 0
        )

)