FOXX S67L Smart Phone SAR Test Report by Morlab Communications

S67L_FCC SAR

This report details the Specific Absorption Rate (SAR) testing of the FOXX S67L Smart Phone, conducted by Shenzhen Morlab Communications Technology Co., Ltd. The device, identified by FCC ID 2AQRM-S67L, was evaluated for compliance with FCC regulations outlined in 47 CFR Part 2 (2.1093) and IEEE standard 1528-2013. The testing encompassed various operational modes and frequency bands, including 5G NR bands n2, n5, n7, n25, n41, n66, n71, n77, and n78.

The report includes detailed information on the test setup, measurement procedures, and equipment used. Tissue simulating liquids were employed to mimic the dielectric properties of human head and body tissues. The SAR values were measured for both head and body exposure scenarios, with specific configurations for cheek/touch positions, tilted positions, and body-worn accessories. Simultaneous transmission scenarios involving WWAN and WLAN were also evaluated.

The maximum reported SAR value was 1.014 W/kg for head exposure and 0.789 W/kg for body-worn exposure. The highest simultaneous transmission SAR was 1.517 W/kg, well below the regulatory limit of 1.6 W/kg. The report concludes that the FOXX S67L Smart Phone complies with the SAR limits for general population/uncontrolled exposure.


File Info : application/pdf, 55 Pages, 2.66MB

Download
WPS 文字
tags: ["S67L", "MIR", "FOXX", "FOXXD", "AIRVOICE", "FOXXD HTH", "2AQRM-S67L", "FCC 47 CFR Part 2 (2.1093)", "IEEE 1528-2013"]
Array
(
    [0] => Array
        (
            [url_sha] => 2abba529c16f860b96fbb9451f0ceef918f2756c3b455c5c9c42043c6d64635d
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8255919
            [href_text] => S67L_FCC SAR
            [href_description] => FOXX Development Inc. S67L Smart Phone 2AQRM-S67L 2AQRMS67L s67l
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8255919
            [http_size] => 2787366
            [file_sha256] => 7a6e2ca9033b0eb4ac79d9640a68390c4a01fdf8c6e822ec2fc62536795e6202
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 7a6e2ca9033b0eb4ac79d9640a68390c4a01fdf8c6e822ec2fc62536795e6202
    [cleanFccId] => 2AQRMS67L
    [title] => FOXX S67L Smart Phone SAR Test Report by Morlab Communications
    [description] => SAR test report for the FOXX S67L Smart Phone, detailing compliance with FCC regulations and IEEE standards. Conducted by Shenzhen Morlab Communications.
    [brand_name] => FOXX
    [keywords] => ["S67L", "MIR", "FOXX", "FOXXD", "AIRVOICE", "FOXXD HTH", "2AQRM-S67L", "FCC 47 CFR Part 2 (2.1093)", "IEEE 1528-2013"]
    [intro] => 

This report details the Specific Absorption Rate (SAR) testing of the FOXX S67L Smart Phone, conducted by Shenzhen Morlab Communications Technology Co., Ltd. The device, identified by FCC ID 2AQRM-S67L, was evaluated for compliance with FCC regulations outlined in 47 CFR Part 2 (2.1093) and IEEE standard 1528-2013. The testing encompassed various operational modes and frequency bands, including 5G NR bands n2, n5, n7, n25, n41, n66, n71, n77, and n78.

The report includes detailed information on the test setup, measurement procedures, and equipment used. Tissue simulating liquids were employed to mimic the dielectric properties of human head and body tissues. The SAR values were measured for both head and body exposure scenarios, with specific configurations for cheek/touch positions, tilted positions, and body-worn accessories. Simultaneous transmission scenarios involving WWAN and WLAN were also evaluated.

The maximum reported SAR value was 1.014 W/kg for head exposure and 0.789 W/kg for body-worn exposure. The highest simultaneous transmission SAR was 1.517 W/kg, well below the regulatory limit of 1.6 W/kg. The report concludes that the FOXX S67L Smart Phone complies with the SAR limits for general population/uncontrolled exposure.

)
Array
(
    [0] => Array
        (
            [id] => 8255919
            [file_sha256] => 
            [applicationId] => 85uqgQl7pg1i7dGZxpatpA==
            [description] => S67L_FCC SAR
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 2787367
            [submissionDate] => 2025-04-30 00:00:00
            [dateAvailable] => 2025-04-30 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2AQRM-S67L
            [cleanFccId] => 2AQRMS67L
            [exif] => 0
        )

)