Picomag Insertion Test Report by Phoenix Testlab GmbH

Test Report

This test report, numbered F240089E4, details the electromagnetic compatibility (EMC) testing of the Picomag Insertion, a magnetic flowmeter manufactured by Endress+Hauser Flowtec AG. The tests were conducted by Phoenix Testlab GmbH in Blomberg, Germany, and the report confirms that the equipment under test (EUT) meets the requirements of FCC 47 CFR Part 15 and ICES-003 standards for Class A equipment.

The report covers both radiated and conducted emissions, with measurements taken across various frequency ranges. The EUT was tested in a normal operating mode with Bluetooth Low Energy (BLE) active, and the results indicate compliance with the specified limits. The test setup, procedures, and equipment used are thoroughly documented, including details on the antenna polarization, turntable azimuth, and resolution bandwidths. The report also includes measurement uncertainties and a list of test equipment used, ensuring transparency and reliability of the results.

The tests were performed between November 4th and November 20th, 2024, and the report was issued on February 6th, 2025. The report includes detailed tables of results, plots of emissions, and references to relevant standards, providing a comprehensive assessment of the Picomag Insertion's EMC performance.


File Info : application/pdf, 25 Pages, 627.49KB

Download
PDFCreator Custom 4.1.3
tags: ["Picomag Insertion", "DMI-AABEA1", "2AIMC-DMI", "21529-DMI", "F240089E4"]
Array
(
    [0] => Array
        (
            [url_sha] => c031c7391f220c73e3c0bd12a152a2739aae7d7272b66ef54b37fc0c1c4f600c
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8063385
            [href_text] => Test Report
            [href_description] => Endress&Hauser; Flowtec AG DMI Magnetic Flowmeter 2AIMC-DMI 2AIMCDMI dmi
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8063385
            [http_size] => 642554
            [file_sha256] => 7a0f44902ca21b8154cda281795077af5965649a2b0637ac6b3f0347cd316184
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 7a0f44902ca21b8154cda281795077af5965649a2b0637ac6b3f0347cd316184
    [cleanFccId] => 2AIMCDMI
    [title] => Picomag Insertion Test Report by Phoenix Testlab GmbH
    [description] => Test report for the Picomag Insertion, conducted by Phoenix Testlab GmbH, ensuring compliance with FCC and ICES standards. 
    [brand_name] => Endress+Hauser
    [keywords] => ["Picomag Insertion", "DMI-AABEA1", "2AIMC-DMI", "21529-DMI", "F240089E4"]
    [intro] => 

This test report, numbered F240089E4, details the electromagnetic compatibility (EMC) testing of the Picomag Insertion, a magnetic flowmeter manufactured by Endress+Hauser Flowtec AG. The tests were conducted by Phoenix Testlab GmbH in Blomberg, Germany, and the report confirms that the equipment under test (EUT) meets the requirements of FCC 47 CFR Part 15 and ICES-003 standards for Class A equipment.

The report covers both radiated and conducted emissions, with measurements taken across various frequency ranges. The EUT was tested in a normal operating mode with Bluetooth Low Energy (BLE) active, and the results indicate compliance with the specified limits. The test setup, procedures, and equipment used are thoroughly documented, including details on the antenna polarization, turntable azimuth, and resolution bandwidths. The report also includes measurement uncertainties and a list of test equipment used, ensuring transparency and reliability of the results.

The tests were performed between November 4th and November 20th, 2024, and the report was issued on February 6th, 2025. The report includes detailed tables of results, plots of emissions, and references to relevant standards, providing a comprehensive assessment of the Picomag Insertion's EMC performance.

)
Array
(
    [0] => Array
        (
            [id] => 8063385
            [file_sha256] => 
            [applicationId] => MyYQGkTeb3pHHypjXRlqjw==
            [description] => Test Report
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => Test Report
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 642555
            [submissionDate] => 2025-02-21 00:00:00
            [dateAvailable] => 2025-02-21 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2AIMC-DMI
            [cleanFccId] => 2AIMCDMI
            [exif] => 0
        )

)