This document presents calibration reports for both a COMOSAR E-Field Probe and a SAR Reference Dipole, performed by MVG (Microwave Vision Group). The E-Field Probe calibration, detailed in report ACR.41.11.25.BES.A, covers the method and results of an accredited calibration using the CALIPROBE test bench. The probe, model SSE2 with serial number SN 04/22 EPGO364, is intended for use with MVG COMOSAR systems. The calibration adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring traceability to the International System of Units (SI).
The SAR Reference Dipole calibration, documented in report ACR.42.17.25.BES.A, presents the method and results from an accredited calibration performed in MVG using the COMOSAR test bench. The dipole, with serial number SN 06/22 DIP2G450-645, operates at a frequency of 2450 MHz. Both calibrations are essential for maintaining the accuracy and reliability of SAR measurement systems, ensuring compliance with regulatory requirements and industry standards. The accreditation numbers 2-6789 and 2-6814 are associated with these calibrations.
Array ( [0] => Array ( [url_sha] => 1601b24db18e6abb564fb3e14826d85688622b7dee07c401c91692630892b741 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8087052 [href_text] => SAR Report part 1 [href_description] => Lightcomm Technology Co., Ltd. MID1110 XMF-MID1110 XMFMID1110 mid1110 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8087052 [http_size] => 5791295 [file_sha256] => 75e966d79d512b83041bd6c1edf96dfd485fb23315b20c6315eac631cc6dfed1 [domain] => document.fccid ) [1] => Array ( [url_sha] => 41f2b0849e6241fe09764ea27ee09ba0d41a80449e981eef159c394e29b8015c [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8086980 [href_text] => SAR Report part 1 [href_description] => Lightcomm Technology Co., Ltd. MID1110 Tablet XMF-MID1110 XMFMID1110 mid1110 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8086980 [http_size] => 5791295 [file_sha256] => 75e966d79d512b83041bd6c1edf96dfd485fb23315b20c6315eac631cc6dfed1 [domain] => document.fccid ) [2] => Array ( [url_sha] => 283023b3e2fe1711a5688363a750bb98c6beaa32b78c2497131c0b45fe255328 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8086916 [href_text] => SAR Report part 1 [href_description] => Lightcomm Technology Co., Ltd. MID1110 Tablet XMF-MID1110 XMFMID1110 mid1110 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8086916 [http_size] => 5791295 [file_sha256] => 75e966d79d512b83041bd6c1edf96dfd485fb23315b20c6315eac631cc6dfed1 [domain] => document.fccid ) ) Array ( [file_sha256] => 75e966d79d512b83041bd6c1edf96dfd485fb23315b20c6315eac631cc6dfed1 [cleanFccId] => XMFMID1110 [title] => COMOSAR E-Field Probe and SAR Dipole Calibration Report [description] => Accredited calibration report for COMOSAR E-Field Probe and SAR Reference Dipole, ensuring accurate measurements and compliance with standards. [brand_name] => MVG (Microwave Vision Group) [keywords] => ["COMOSAR", "E-Field Probe", "DIP2G450-645", "EPGO364", "SSE2", "ACR.41.11.25.BES.A", "ACR.42.17.25.BES.A", "IEC/IEEE 62209-1528", "FCC KDB865664 D01", "2-6789", "2-6814"] [intro] =>This document presents calibration reports for both a COMOSAR E-Field Probe and a SAR Reference Dipole, performed by MVG (Microwave Vision Group). The E-Field Probe calibration, detailed in report ACR.41.11.25.BES.A, covers the method and results of an accredited calibration using the CALIPROBE test bench. The probe, model SSE2 with serial number SN 04/22 EPGO364, is intended for use with MVG COMOSAR systems. The calibration adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring traceability to the International System of Units (SI).
The SAR Reference Dipole calibration, documented in report ACR.42.17.25.BES.A, presents the method and results from an accredited calibration performed in MVG using the COMOSAR test bench. The dipole, with serial number SN 06/22 DIP2G450-645, operates at a frequency of 2450 MHz. Both calibrations are essential for maintaining the accuracy and reliability of SAR measurement systems, ensuring compliance with regulatory requirements and industry standards. The accreditation numbers 2-6789 and 2-6814 are associated with these calibrations.
)
Array ( [0] => Array ( [id] => 8086916 [file_sha256] => [applicationId] => yKjCHeZz5KsET4j1Bir9kA== [description] => SAR Report part 1 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 5791297 [submissionDate] => 2025-03-03 00:00:00 [dateAvailable] => 2025-03-03 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => XMF-MID1110 [cleanFccId] => XMFMID1110 [exif] => 0 ) )