This document contains a collection of calibration reports for COMOSAR E-Field Probes and reference dipoles, produced by MVG (Microwave Vision Group). These reports detail the methods and results of accredited calibrations performed at MVG, utilizing the CALIPROBE test bench for E-Field Probes and COMOSAR test bench for dipoles. The calibrations are essential for ensuring the accuracy and reliability of SAR (Specific Absorption Rate) measurements.
The reports include information on the device under test, product description, measurement methods, and calibration results. Key parameters such as sensitivity in air and liquid, linearity, isotropy, return loss, and impedance are evaluated. Measurement uncertainties are also thoroughly assessed. The calibration process adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring traceability to the International System of Units (SI). The reports also list the equipment used during the calibration process.
These reports are crucial for validating SAR measurement systems and ensuring compliance with regulatory requirements. The calibration data provided enables accurate assessment of electromagnetic field exposure from wireless devices.
Array ( [0] => Array ( [url_sha] => cd59dc7f957de5249cd1af7c0072b786892e685857908a3cbaf52d888d6df35f [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8059607 [href_text] => SAR Report [href_description] => BLUEBIRD INC. SP60W1 Smart Pos Payment Terminal SS4SP60W1 SS4SP60W1 sp60w1 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8059607 [http_size] => 4828292 [file_sha256] => 74b87a16613406ff59fad59b0a4d96cb6d6b89385f6481a665d74341474f92d4 [domain] => document.fccid ) [1] => Array ( [url_sha] => 573fb89c2944bb0dae8e3561b2e73509a1e6dd11c20fe8c8d433d2f14ef9b899 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8059546 [href_text] => SAR Report [href_description] => BLUEBIRD INC. SP60W1 Smart Pos Payment Terminal SS4SP60W1 SS4SP60W1 sp60w1 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8059546 [http_size] => 4828292 [file_sha256] => 74b87a16613406ff59fad59b0a4d96cb6d6b89385f6481a665d74341474f92d4 [domain] => document.fccid ) [2] => Array ( [url_sha] => 17fe5814b513f866f702da7365b64c237b69e456a279b654cbc7674f70ca1bf0 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8059604 [href_text] => SAR Report [href_description] => BLUEBIRD INC. SP60W1 Smart Pos Payment Terminal SS4SP60W1 SS4SP60W1 sp60w1 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8059604 [http_size] => 4828292 [file_sha256] => 74b87a16613406ff59fad59b0a4d96cb6d6b89385f6481a665d74341474f92d4 [domain] => document.fccid ) ) Array ( [file_sha256] => 74b87a16613406ff59fad59b0a4d96cb6d6b89385f6481a665d74341474f92d4 [cleanFccId] => SS4SP60W1 [title] => COMOSAR E-Field Probe and Dipole Calibration Reports [description] => Accredited calibration reports for COMOSAR E-Field Probe and reference dipoles used in SAR measurement systems. [brand_name] => MVG (Microwave Vision Group) [keywords] => ["SSE2", "SN 04/22 EPGO364", "SID2450", "SN 06/22 DIP2G450-645", "SID5000", "SN 06/22 DIP5G000-653", "ACR.41.17.24.BES.A", "ACR.42.13.22.BES.A", "ACR.42.21.22.BES.A"] [intro] =>This document contains a collection of calibration reports for COMOSAR E-Field Probes and reference dipoles, produced by MVG (Microwave Vision Group). These reports detail the methods and results of accredited calibrations performed at MVG, utilizing the CALIPROBE test bench for E-Field Probes and COMOSAR test bench for dipoles. The calibrations are essential for ensuring the accuracy and reliability of SAR (Specific Absorption Rate) measurements.
The reports include information on the device under test, product description, measurement methods, and calibration results. Key parameters such as sensitivity in air and liquid, linearity, isotropy, return loss, and impedance are evaluated. Measurement uncertainties are also thoroughly assessed. The calibration process adheres to IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards, ensuring traceability to the International System of Units (SI). The reports also list the equipment used during the calibration process.
These reports are crucial for validating SAR measurement systems and ensuring compliance with regulatory requirements. The calibration data provided enables accurate assessment of electromagnetic field exposure from wireless devices.
)
Array ( [0] => Array ( [id] => 8059546 [file_sha256] => [applicationId] => I6s2FV3WYxrv8mnd6CAxBw== [description] => SAR Report [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4828294 [submissionDate] => 2025-02-20 00:00:00 [dateAvailable] => 2025-02-20 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => SS4SP60W1 [cleanFccId] => SS4SP60W1 [exif] => 0 ) )