D2450V2-SN: 904 System Validation Plots for RF Exposure Testing

RF Exposure Info-A

This document presents the system validation plots for RF exposure testing conducted on the D2450V2-SN: 904 device. The testing was performed by Guangdong Dongdian Testing Service Co., Ltd. on January 4, 2025. The report number associated with this testing is DDT-RE25032623-2E07.

The validation process utilized a Dipole 2450 MHz D2450V2, with serial number D2450V2 - SN:904. The communication system employed was CW (Continuous Wave) at a frequency of 2450 MHz. Medium parameters used were f = 2450 MHz; σ = 1.817 S/m; 2 = 40.245; p = 1000 kg/m³. The phantom section was a flat section, and the measurement standard followed DASY5 (IEEE/IEC/ANSI C63.19-2011) guidelines.

The DASY configuration included an EX3DV4 probe (SN3906) calibrated on April 29, 2024, and a DAE4 electronics unit (Sn1366) also calibrated on April 29, 2024. The area and zoom scans were performed with specific grid configurations, and the resulting SAR values were recorded. The SAR(1 g) value was measured at 12.6 W/kg, and the SAR(10 g) value was 5.94 W/kg.


File Info : application/pdf, 3 Pages, 368.67KB

Download
Microsoft Word 2019 Microsoft Word 2019
N/A: D2450V2, D2450V2-SN: 904, RE25032623-2E07, System Validation Plots, RF Exposure