This document presents the FCC RF Exposure report for Thermal Imagers, conducted by BlueAsia of Technical Services (Shenzhen) Co., Ltd. The report assesses the device's compliance with FCC regulations regarding radio frequency exposure limits, ensuring it meets safety standards for public use.
The evaluation covers the Thermal Imagers, specifically models HT A201, HT A202, and HT A203, manufactured by Dongguan Xintai Instrument Co., Ltd. The assessment adheres to 47 CFR Part 15, Part1.1307, 47 CFR Part 15, Part2.1093, and KDB447498D04 General RF Exposure Guidance v01. Testing was conducted between December 19, 2024, and January 08, 2025, with the report issued on January 20, 2025.
The report concludes that the Thermal Imagers comply with RF exposure exemption limits, as the calculated ERP value is below the specified threshold. This determination is based on the device's output power, antenna gain, and operating frequencies within the 2.4GHz band. The device utilizes a PCB antenna with a gain of 3dBi and operates on battery power at DC 3.70V.
Array ( [0] => Array ( [url_sha] => 48d7f03c3b43bfbcbe5c0a2bbda9701930ab04beeb464cae8927b1d72d20ccff [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8074802 [href_text] => RF EXPO [href_description] => Dongguan Xintai Instrument Co.,Ltd. A201 Thermal Imagers 2AVBO-A201 2AVBOA201 a201 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8074802 [http_size] => 339845 [file_sha256] => 67e3555507251dac842ea141b9795eca4988ca132654f73998d388e0f144c947 [domain] => document.fccid ) ) Array ( [file_sha256] => 67e3555507251dac842ea141b9795eca4988ca132654f73998d388e0f144c947 [cleanFccId] => 2AVBOA201 [title] => FCC RF Exposure Report for Thermal Imagers by BlueAsia [description] => This report details the RF exposure compliance assessment for Thermal Imagers, ensuring adherence to FCC standards and safety guidelines. [brand_name] => BlueAsia [keywords] => ["HT A201", "HT A202", "HT A203", "Thermal Imagers", "2AVBO-A201"] [intro] =>This document presents the FCC RF Exposure report for Thermal Imagers, conducted by BlueAsia of Technical Services (Shenzhen) Co., Ltd. The report assesses the device's compliance with FCC regulations regarding radio frequency exposure limits, ensuring it meets safety standards for public use.
The evaluation covers the Thermal Imagers, specifically models HT A201, HT A202, and HT A203, manufactured by Dongguan Xintai Instrument Co., Ltd. The assessment adheres to 47 CFR Part 15, Part1.1307, 47 CFR Part 15, Part2.1093, and KDB447498D04 General RF Exposure Guidance v01. Testing was conducted between December 19, 2024, and January 08, 2025, with the report issued on January 20, 2025.
The report concludes that the Thermal Imagers comply with RF exposure exemption limits, as the calculated ERP value is below the specified threshold. This determination is based on the device's output power, antenna gain, and operating frequencies within the 2.4GHz band. The device utilizes a PCB antenna with a gain of 3dBi and operates on battery power at DC 3.70V.
)
Array ( [0] => Array ( [id] => 8074802 [file_sha256] => [applicationId] => 9DqXEwb1ucd1JNZak7FQDA== [description] => RF EXPO [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 339846 [submissionDate] => 2025-02-26 00:00:00 [dateAvailable] => 2025-02-26 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2AVBO-A201 [cleanFccId] => 2AVBOA201 [exif] => 0 ) )