This document contains system performance check reports generated by UL LLC SAR 2A. These reports detail the procedures and results of system validation tests conducted on specific dates to ensure the accuracy and reliability of SAR (Specific Absorption Rate) measurements. The reports include information on the hardware setup, scan parameters, and measurement results for various frequencies.
Each report provides a summary of the test, including the dipole model used, frequency, phantom section, and power level. It also outlines the exposure conditions, such as dipole distance and conversion factor. The hardware setup section details the probe and DAE models used, along with their calibration dates. The scan setup section describes the grid extents and steps for both area and zoom scans. Finally, the measurement results section presents the psSAR1g and psSAR10g values, as well as the power drift.
The reports also include visual representations of the SAR distribution, providing a clear indication of the energy absorption patterns during the tests. These reports are essential for verifying the performance of the SAR measurement system and ensuring the validity of SAR test results.
Array ( [0] => Array ( [url_sha] => 933711504f93fcb5de511570365e26b2161c06dcd58be19e45082f59f9b984fa [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8257452 [href_text] => SAR Report Appendix B [href_description] => Hill-Rom, Inc P0100HF Communication Module 2AOL2-P0100HF 2AOL2P0100HF p0100hf [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8257452 [http_size] => 189310 [file_sha256] => 6416e3f5ee1dd9dcd60bfaf71ff744574b439217df8e404f990bbc866432c54b [domain] => document.fccid ) [1] => Array ( [url_sha] => 05baf5ddbbc9920f4bea80217fea162c83273e33a882e03b8880c8b5f8334e2c [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8257499 [href_text] => SAR Report Appendix B [href_description] => Hill-Rom, Inc P0100HF Communication Module 2AOL2-P0100HF 2AOL2P0100HF p0100hf [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8257499 [http_size] => 189310 [file_sha256] => 6416e3f5ee1dd9dcd60bfaf71ff744574b439217df8e404f990bbc866432c54b [domain] => document.fccid ) ) Array ( [file_sha256] => 6416e3f5ee1dd9dcd60bfaf71ff744574b439217df8e404f990bbc866432c54b [cleanFccId] => 2AOL2P0100HF [title] => UL LLC SAR 2A System Performance Check Report [description] => System performance check reports for SAR testing, detailing hardware setup, scan parameters, and measurement results for various frequencies. [brand_name] => UL LLC [keywords] => ["D2450V2", "SN963", "D5GHzV2", "SN1213", "EX3DV4", "SN7711", "DAE4", "Sn1716", "ELI V8.0", "SN2160", "HBBL-600-10000"] [intro] =>This document contains system performance check reports generated by UL LLC SAR 2A. These reports detail the procedures and results of system validation tests conducted on specific dates to ensure the accuracy and reliability of SAR (Specific Absorption Rate) measurements. The reports include information on the hardware setup, scan parameters, and measurement results for various frequencies.
Each report provides a summary of the test, including the dipole model used, frequency, phantom section, and power level. It also outlines the exposure conditions, such as dipole distance and conversion factor. The hardware setup section details the probe and DAE models used, along with their calibration dates. The scan setup section describes the grid extents and steps for both area and zoom scans. Finally, the measurement results section presents the psSAR1g and psSAR10g values, as well as the power drift.
The reports also include visual representations of the SAR distribution, providing a clear indication of the energy absorption patterns during the tests. These reports are essential for verifying the performance of the SAR measurement system and ensuring the validity of SAR test results.
)
Array ( [0] => Array ( [id] => 8257452 [file_sha256] => [applicationId] => Qbsb9xfK111+CL61aLkWLg== [description] => SAR Report Appendix B [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 189312 [submissionDate] => 2025-05-01 00:00:00 [dateAvailable] => 2025-05-01 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2AOL2-P0100HF [cleanFccId] => 2AOL2P0100HF [exif] => 0 ) )