This document presents the Specific Absorption Rate (SAR) test report for the Sepura SC2124 TETRA portable radio. The tests were conducted by DEKRA Testing and Certification, S.A.U., adhering to IEEE Std 1528-2013 and FCC 47 CFR Part 2.1093 standards. The device was evaluated for head and body-worn exposure conditions, with various accessories. The maximum 1g volume averaged SAR found during the tests was 2.717 W/kg for TETRA mode.
The report details the test setup, measurement system, tissue parameters, and results. The device was found to be in compliance with FCC 47CFR Part 2.1093 exposure limits. The report includes information on the device's features (TETRA, BT, Wi-Fi, GNSS), manufacturer (Sepura Limited), and various accessories used during testing. The document also provides a detailed uncertainty analysis and system validation report.
The test results confirm that the Sepura SC2124 TETRA portable radio meets the required safety standards for radio frequency exposure.