This document presents an RF exposure evaluation conducted by Anbotek for the device with FCC ID 2BDJR-SKM64. The evaluation adheres to KDB 447498 D01 guidelines for mobile and portable devices, as well as FCC regulations outlined in 1.1310. The primary objective is to assess the potential impact of human exposure to radio frequency (RF) radiation emitted by the device.
The evaluation employs SAR test exclusion thresholds for frequencies between 100 MHz and 6 GHz, considering test separation distances of ≤50 mm. The calculations are based on the maximum power of the channel, including tune-up tolerance, and the minimum test separation distance. The results are compared against established limits to determine compliance.
The findings indicate that the device meets the SAR test exclusion criteria, and therefore, no standalone SAR test is required. This conclusion is based on the calculated values, which are below the specified limits. The evaluation provides detailed information on the channel frequencies, output power, tune-up tolerance, and calculation results, supporting the determination of RF exposure compliance.