This document presents an RF exposure evaluation for a Remote Controller, identified by the FCC ID OZ5C502. The evaluation is conducted in accordance with FCC regulations, specifically 47CFR § 2.1093 and KDB-447498 D01 V06, to demonstrate compliance with RF exposure limits. The report includes measurements of average conducted output power, target power with tolerance, and maximum average output power for different frequencies (2402 MHz, 2440 MHz, and 2480 MHz).
The evaluation calculates the RF exposure level based on the formula [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] *[√f(GHz)]. The results indicate that the maximum RF exposure is 1.25, which is below the threshold of 3 for 1-g SAR, given a separation distance of 5 mm. Therefore, based on these findings, the report concludes that no Specific Absorption Rate (SAR) testing is required for this device.
Array ( [0] => Array ( [url_sha] => 545190a0bd8d0e01ecba75e95805ae129e9c2aadec272f2a491dde49e0fb4ef3 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8300247 [href_text] => RF Exposure [href_description] => Ohsung Electronics Co., Ltd. C502 Remote Controller OZ5C502 OZ5C502 c502 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8300247 [http_size] => 208025 [file_sha256] => 618e5fdf8930e50a791a14a410f24881731c0ec15ca72f1b5861cdb8fc055164 [domain] => document.fccid ) ) Array ( [file_sha256] => 618e5fdf8930e50a791a14a410f24881731c0ec15ca72f1b5861cdb8fc055164 [cleanFccId] => OZ5C502 [title] => RF Exposure Evaluation Report for Remote Controller OZ5C502 [description] => This report evaluates RF exposure compliance for the Remote Controller OZ5C502, ensuring adherence to FCC regulations and safety standards. [brand_name] => GETEC [keywords] => ["OZ5C502", "GETEC-C1-25-114", "GETEC-E3-25-015", "Remote Controller", "FCC Part 15 subpart C", "RF Exposure Evaluation"] [intro] =>This document presents an RF exposure evaluation for a Remote Controller, identified by the FCC ID OZ5C502. The evaluation is conducted in accordance with FCC regulations, specifically 47CFR § 2.1093 and KDB-447498 D01 V06, to demonstrate compliance with RF exposure limits. The report includes measurements of average conducted output power, target power with tolerance, and maximum average output power for different frequencies (2402 MHz, 2440 MHz, and 2480 MHz).
The evaluation calculates the RF exposure level based on the formula [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] *[√f(GHz)]. The results indicate that the maximum RF exposure is 1.25, which is below the threshold of 3 for 1-g SAR, given a separation distance of 5 mm. Therefore, based on these findings, the report concludes that no Specific Absorption Rate (SAR) testing is required for this device.
)
Array ( [0] => Array ( [id] => 8300247 [file_sha256] => [applicationId] => ImhtLJ2WB+w3r+f3utz8Xg== [description] => RF Exposure [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 208025 [submissionDate] => 2025-05-16 00:00:00 [dateAvailable] => 2025-05-16 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => OZ5C502 [cleanFccId] => OZ5C502 [exif] => 0 ) )