This document presents the test results for 26dB Bandwidth and Occupied Bandwidth measurements conducted on a device identified by report number TCWA25010004602. The tests were performed to ensure the device complies with specified regulatory requirements for bandwidth emissions. The report includes detailed measurements for various modulation schemes, bandwidth configurations, and channel settings.
The tests were conducted using an Agilent Spectrum Analyzer, and the results are presented in both tabular and graphical formats. The tabular data includes the measured 99% occupied bandwidth and 26dB bandwidth for different configurations, including DFT-BPSK, DFT-QPSK, DFT-16QAM, DFT-64QAM, DFT-256QAM, CP-QPSK, CP-16QAM, CP-64QAM, and CP-256QAM modulations. The graphical representations provide a visual depiction of the bandwidth characteristics under different test conditions.
The test results indicate that the device meets the required bandwidth specifications for all tested configurations. The report provides a comprehensive overview of the device's bandwidth performance, supporting its compliance with relevant regulatory standards.
Array ( [0] => Array ( [url_sha] => 724beb92026429b3e6e571bfe99defa5f41262395ff8ee243e97f8ddfd4f5bc0 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8254601 [href_text] => Test Report5 [href_description] => Sercomm Corporation TMOG5SEM G5SEM P27-TMOG5SEM P27TMOG5SEM tmog5sem [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8254601 [http_size] => 4889382 [file_sha256] => 5a0dda3bf631744859be7c3d784d5462fbf520fb29f519f58150ce5e22a80050 [domain] => document.fccid ) ) Array ( [file_sha256] => 5a0dda3bf631744859be7c3d784d5462fbf520fb29f519f58150ce5e22a80050 [cleanFccId] => P27TMOG5SEM [title] => TCWA25010004602: 26dB Bandwidth and Occupied Bandwidth Test Report [description] => This test report details the 26dB bandwidth and occupied bandwidth measurements for the TCWA25010004602 device, ensuring compliance. [brand_name] => TOWE [keywords] => ["TCWA25010004602", "n48", "DFT-BPSK", "DFT-QPSK", "DFT-16QAM", "DFT-64QAM", "DFT-256QAM", "CP-QPSK", "CP-16QAM", "CP-64QAM", "CP-256QAM"] [intro] =>This document presents the test results for 26dB Bandwidth and Occupied Bandwidth measurements conducted on a device identified by report number TCWA25010004602. The tests were performed to ensure the device complies with specified regulatory requirements for bandwidth emissions. The report includes detailed measurements for various modulation schemes, bandwidth configurations, and channel settings.
The tests were conducted using an Agilent Spectrum Analyzer, and the results are presented in both tabular and graphical formats. The tabular data includes the measured 99% occupied bandwidth and 26dB bandwidth for different configurations, including DFT-BPSK, DFT-QPSK, DFT-16QAM, DFT-64QAM, DFT-256QAM, CP-QPSK, CP-16QAM, CP-64QAM, and CP-256QAM modulations. The graphical representations provide a visual depiction of the bandwidth characteristics under different test conditions.
The test results indicate that the device meets the required bandwidth specifications for all tested configurations. The report provides a comprehensive overview of the device's bandwidth performance, supporting its compliance with relevant regulatory standards.
)
Array ( [0] => Array ( [id] => 8254601 [file_sha256] => [applicationId] => GVop1tk+LVbH5BCWCKd+kQ== [description] => Test Report5 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => Test Report [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4889384 [submissionDate] => 2025-04-30 00:00:00 [dateAvailable] => 2025-04-30 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => P27-TMOG5SEM [cleanFccId] => P27TMOG5SEM [exif] => 0 ) )